Logotipo do repositório

Agreement analysis of oscillometric devices in the measure of resting heart rate in breast cancer survivors

dc.contributor.authorPalma, Mariana R. [UNESP]
dc.contributor.authorVanderlei, Luiz C.M. [UNESP]
dc.contributor.authorRibeiro, Fernanda E. [UNESP]
dc.contributor.authorDe Andrade, Rafaela C.C. [UNESP]
dc.contributor.authorFregonesi, Cristina E.P.T. [UNESP]
dc.contributor.authorFreitas Júnior, Ismael F. [UNESP]
dc.contributor.authorChristofaro, Diego G.D. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T16:52:25Z
dc.date.available2018-12-11T16:52:25Z
dc.date.issued2018-01-01
dc.description.abstractObjectiveThe aim of this study was to verify the reproducibility of an oscillometric device in the measurement of resting heart rate (RHR) in breast cancer survivors.MethodsThis study included 85 breast cancer survivors with a mean age of 58.87±10.03 years. For the RHR evaluation, the equipment used was the Omron HEM 742, electronic and digital arm device, for measurement of blood pressure and heart rate (HR), with automatic cuff inflation and deflation. At the same time as the oscillometric measurement, HR was measured by the HR monitor Polar RS800 CX, which has been validated previously for HR uptake. The HR value obtained by the cardiofrequency meter was registered at the same time that the Omron device measured blood pressure and HR values.ResultsIt was observed that the RHR values were very close in both devices and that the correlation values and intraclass correlation coefficient were high. These results were replicated when the female breast cancer survivors were stratified by age group. The agreement values presented by the Bland-Altman analysis showed good values; both for the entire sample and stratified by age, few cases were outside beyond 95% confidence interval range.ConclusionThe present study showed that the oscillometric device used presented good values of reproducibility in the detection of RHR values in breast cancer survivors compared with a cardiac monitor.en
dc.description.affiliationDepartment of Physical Education School of Technology and Sciences School of Technology and Sciences São Paulo State University (UNESP), Rua Roberto Simonsen, 305
dc.description.affiliationUnespDepartment of Physical Education School of Technology and Sciences School of Technology and Sciences São Paulo State University (UNESP), Rua Roberto Simonsen, 305
dc.format.extent33-36
dc.identifierhttp://dx.doi.org/10.1097/MBP.0000000000000303
dc.identifier.citationBlood Pressure Monitoring, v. 23, n. 1, p. 33-36, 2018.
dc.identifier.dimensionspub.1092642373
dc.identifier.doi10.1097/MBP.0000000000000303
dc.identifier.issn1473-5725
dc.identifier.issn1359-5237
dc.identifier.orcid0000-0001-9917-9992
dc.identifier.orcid0000-0002-5071-0428
dc.identifier.orcid0000-0002-8228-1330
dc.identifier.orcid0000-0003-0395-0899
dc.identifier.pmid29135491
dc.identifier.scopus2-s2.0-85044124687
dc.identifier.urihttp://hdl.handle.net/11449/170789
dc.language.isoeng
dc.publisherWolters Kluwer
dc.relation.ispartofBlood Pressure Monitoring
dc.relation.ispartofsjr0,537
dc.rights.accessRightsAcesso restritopt
dc.sourceScopus
dc.sourceDimensions
dc.subjectarterial pressure
dc.subjectbreast neoplasms
dc.subjectcardiovascular
dc.subjectdiagnostic techniques
dc.subjectheart rate
dc.titleAgreement analysis of oscillometric devices in the measure of resting heart rate in breast cancer survivorsen
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublicationbbcf06b3-c5f9-4a27-ac03-b690202a3b4e
relation.isOrgUnitOfPublication.latestForDiscoverybbcf06b3-c5f9-4a27-ac03-b690202a3b4e
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Ciências e Tecnologia, Presidente Prudentept

Arquivos