Logotipo do repositório
 

Publicação:
Exploring potentialities of the HR-CS FAAS technique in the determination of Ni and Pb in mineral waters

dc.contributor.authorFilho, V. R. Amorim [UNESP]
dc.contributor.authorFranzini, V. P. [UNESP]
dc.contributor.authorNeto, J. A. Gomes [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.date.accessioned2022-04-29T08:35:02Z
dc.date.available2022-04-29T08:35:02Z
dc.date.issued2008-01-01
dc.description.abstractNational Health Surveillance Agency (ANVISA) established in the decree number 54 maximum allowed levels for Ni and Pb in mineral and natural waters at 20 μg L-1 and 10 μg L-1, respectively. For screening analysis purposes, the high-resolution continuum source flame atomic absorption spectrometry technique (HR-CS FAAS) was evaluated for the fast-sequential determination of nickel and lead in mineral waters.Two atomic lines for Ni (232.003 nm - main and 341.477 nm - secondary) and Pb (217.0005 nm - main and 283.306 nm - secondary) at different wavelength integrated absorbance (number of pixels) were evaluated. Sensitivity enhanced with the increase of the number of pixels and with the summation of the atomic lines absorbances. The main figures of merit associated to the HR-CS FAAS technique were compared with that obtained by line-source flame atomic absorption spectrometry (LS FAAS). Water samples were pre-concentrated about 5-fold by evaporation before analysis. Recoveries of Pb significantly varied with increased wavelength integrated absorbance. Better recoveries (92-93%) were observed for higher number of pixels at the main line or summating the atomic lines (90-92%). This influence was irrelevant for Ni, and recoveries in the 92- 104% range were obtained in all situations.en
dc.description.affiliationDepartamento de Química Analítica Instituto de Química Universidade Estadual Paulista, P.O. Box 355 - SP
dc.description.affiliationUnespDepartamento de Química Analítica Instituto de Química Universidade Estadual Paulista, P.O. Box 355 - SP
dc.format.extent49-56
dc.identifierhttp://dx.doi.org/10.26850/1678-4618EQJ.V33.1.2008.P49-56
dc.identifier.citationEcletica Quimica, v. 33, n. 1, p. 49-56, 2008.
dc.identifier.doi10.26850/1678-4618EQJ.V33.1.2008.P49-56
dc.identifier.issn1678-4618
dc.identifier.issn0100-4670
dc.identifier.scopus2-s2.0-85116731961
dc.identifier.urihttp://hdl.handle.net/11449/229671
dc.language.isoeng
dc.relation.ispartofEcletica Quimica
dc.sourceScopus
dc.subjectHR-CS FAAS
dc.subjectMineral water
dc.subjectNi
dc.subjectPb
dc.subjectScreening analysis
dc.titleExploring potentialities of the HR-CS FAAS technique in the determination of Ni and Pb in mineral watersen
dc.typeArtigo
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt

Arquivos