Logotipo do repositório
 

Publicação:
Análise fotoelástica de tensões em próteses obturadoras palatinas implantorretidas, sobre implantes paralelos ou inclinados, associados a diferentes tipos de sistemas de retenção

dc.contributor.advisorGoiato, Marcelo Coelho [UNESP]
dc.contributor.advisorFajardo, Renato Salviato [UNESP]
dc.contributor.authorPesqueira, Aldieris Alves [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-06-11T19:35:03Z
dc.date.available2014-06-11T19:35:03Z
dc.date.issued2012-10-05
dc.description.abstractOs defeitos maxilares podem reduzir drasticamente a eficiência mastigatória e a retenção das próteses destes pacientes. Logo, a associação dos implantes aos sistemas de retenção proporcionou uma nova alternativa de reabilitação para tais casos. Entretanto, a literatura é escassa em relação ao comportamento biomecânico dos diferentes sistemas de retenção em próteses obturadoras palatinas implantorretidas, principalmente em relação às tensões geradas ao implante e tecido ósseo de suporte. Desse modo, este estudo teve como propósito avaliar a distribuição de tensões, por meio do método fotoelástico, em próteses obturadoras palatinas implantorretidas, sobre implantes paralelos ou inclinados associados a diferentes tipos de sistemas de retenção. Foram confeccionados três modelos fotoelásticos a partir de um modelo maxilar experimental com comunicação buco-sinusal divididos em: modelo sem implante (SI), modelo com três implantes paralelos (IP) e modelo com dois implantes paralelos entre si (incisivo e canino) e outro inclinado (angulação distal 17°), na região de molar (II). Posteriormente, foi confeccionada uma prótese obturadora convencional (controle) e quatro próteses obturadoras palatinas implantorretidas para cada modelo com implante (IP e II) com respectivos sistemas de retenção: OR - com três O-rings individualizados, BC - barra-clip, BOC - implantes esplintados por meio de barras associados a dois O-rings posicionados no centro da barra e, BOD - implantes esplintados por meio de barras com clipes associados a dois O-rings posicionados distalmente em cantilever. O conjunto (modelo/sistema de retenção/prótese) foi posicionado em um polariscópio circular, e sobre o mesmo foi aplicada uma carga de 100N, na região de incisivo central, canino e primeiro molar (região com implantes) com o auxílio...pt
dc.description.abstractMaxillary defects may drastically affect the masticatory efficiency and the retention of dentures of several patients. The use of implants associated with attachment systems brought a new alternative of oral rehabilitation in these cases. However, the biomechanical behavior of the different attachment systems used with implant-retained maxillary obturator dentures is still scarce in the literature in regards to stress generated over the implants and bone tissue. Thus, the current study used a photoelastic analysis to investigate the stress distribution in implant-retained maxillary obturator dentures over parallel or tilted implants associated with different attachment systems. A total of three photoelastic models based on an experimental maxillary model with oroantral communication were developed, and they were divided as follow: model without implants (SI), model with three parallel implants (IP) and model with two parallel implants (incisive and canine areas) and one tilted implant (distal angulation of 17 degrees) in the molar region (II). Afterwards, a conventional obturator denture (control) and four implant-retained obturator dentures for each implant model (IP and II) were fabricated. In the IP and II groups different attachment systems were used: OR – three independent O’rings, BC – bar-clip, BOC – splinted implants with bar associated with two O’rings placed in the center part of each bar, and BOD – splinted implants with bar-clip associated with two distally placed O’rings (in cantilever). The set (model/attachment system/denture) was placed in a circular polariscope, and a 100-N load was applied either in the central incisor, canine or first molar regions using an universal testing machine (EMIC DL-3000). The results were obtained based on the photographic records of the stress in the... (Complete abstract click electronic access below)en
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipNeodent
dc.format.extent99 f. : il. + 1 CD-ROM
dc.identifier.aleph000716069
dc.identifier.capes33004021011P0
dc.identifier.citationPESQUEIRA, Aldiéris Alves. Análise fotoelástica de tensões em próteses obturadoras palatinas implantorretidas, sobre implantes paralelos ou inclinados, associados a diferentes tipos de sistemas de retenção. 2012. 99 f. Tese (doutorado) - Universidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Odontologia de Araçatuba, 2012.
dc.identifier.filepesqueira_aa_dr_araca.pdf
dc.identifier.lattes9719883814872582
dc.identifier.lattes2924681675943738
dc.identifier.urihttp://hdl.handle.net/11449/105555
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso abertopt
dc.sourceAleph
dc.subjectImplantes dentáriospt
dc.subjectObturadores palatinospt
dc.subjectProtese maxilo-facialpt
dc.subjectPrótese dentária fixada por implantept
dc.subjectDental implantspt
dc.titleAnálise fotoelástica de tensões em próteses obturadoras palatinas implantorretidas, sobre implantes paralelos ou inclinados, associados a diferentes tipos de sistemas de retençãopt
dc.typeTese de doutoradopt
dspace.entity.typePublication
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.advisor.lattes2924681675943738[2]
unesp.author.lattes9719883814872582
unesp.author.lattes2336450644149867
unesp.author.orcid0000-0003-3020-5253
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.graduateProgramOdontologia - FOApt
unesp.knowledgeAreaPrótese dentáriapt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
pesqueira_aa_dr_araca.pdf
Tamanho:
1.95 MB
Formato:
Adobe Portable Document Format