Logo do repositório

Influence of Light-Curing Time and Increment Thickness on the Properties of Bulk Fill Composite Resins With Distinct Application Systems

dc.contributor.authorTorres, Carlos Rocha Gomes [UNESP]
dc.contributor.authorPrado, Taiana Paola [UNESP]
dc.contributor.authorÁvila, Daniele Mara da Silva [UNESP]
dc.contributor.authorPucci, Cesar Rogério [UNESP]
dc.contributor.authorBorges, Alessandra Bühler [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.date.accessioned2025-04-29T20:07:12Z
dc.date.issued2024-01-01
dc.description.abstractThe objective of this study was to evaluate the influence of light-curing time and increment thickness on the microhardness and degree of conversion (DC) of bulk fill composite resins with different application systems. Translucency parameter (TP) was also measured. Specimens of resin composites were prepared in a circular matrix using a single increment with different thicknesses (2, 4, and 6 mm) and light-cured with distinct times (10, 20, and 40 s). The materials tested (n = 5 pergroup) were Filtek One (FO) bulk fill, Tetric N-Ceram (TC) bulk fill, SonicFill 3 (SF), VisCalor (VC) bulk. After 24 h, Knoop microhardness (KN) was measured, and the bottom/top ratio (B/Tratio) was calculated. The DC was measured using Fourier transformed infrared (FTIR) spectroscopy. The TP was assessed in additional specimens with 1 mm thick (n = 5). The data were statistically analyzed with analysis of variance (ANOVA) and Tukey’s tests (5%). Significant differences were observed for all factors, for both B/Tratio and DC (p < 0.05). The higher increment thickness and the lower curing times resulted in lower B/Tratio and DC means. The VC and TC resins exhibited the overall higher B/Tratio, and the highest TP. SF presented the lowest values of B/Tratio and DC, with compromised polymerization at 6 mm depth. TP (means ± SD) were FO (12.85 ± 1.0)1, SF (15.62 ± 0.73)2, TC (20.32 ± 0.49)3, and VC (20.53 ± 0.73)3. We concluded that the greater the thickness of the increment, the lower the DC. Higher light curing times resulted on increased DC of the tested composites. The higher translucent materials VC and TC showed the greater B/Tratio; and FO resin exhibited the higher DC values.en
dc.description.affiliationDepartment of Restorative Dentistry Institute of Science and Technology Sao Paulo State University—UNESP
dc.description.affiliationUnespDepartment of Restorative Dentistry Institute of Science and Technology Sao Paulo State University—UNESP
dc.identifierhttp://dx.doi.org/10.1155/2024/2123406
dc.identifier.citationInternational Journal of Dentistry, v. 2024, n. 1, 2024.
dc.identifier.doi10.1155/2024/2123406
dc.identifier.issn1687-8736
dc.identifier.issn1687-8728
dc.identifier.scopus2-s2.0-105001564125
dc.identifier.urihttps://hdl.handle.net/11449/306813
dc.language.isoeng
dc.relation.ispartofInternational Journal of Dentistry
dc.sourceScopus
dc.subjectcomposite resins
dc.subjectdegree of conversion
dc.subjectdepth of cure; hardness; translucency
dc.titleInfluence of Light-Curing Time and Increment Thickness on the Properties of Bulk Fill Composite Resins With Distinct Application Systemsen
dc.typeArtigopt
dspace.entity.typePublication
unesp.author.orcid0000-0002-9485-5514[1]
unesp.author.orcid0000-0001-8655-2284[2]
unesp.author.orcid0000-0002-0867-5673[3]
unesp.author.orcid0000-0003-4830-0400[4]
unesp.author.orcid0000-0001-7686-089X[5]

Arquivos

Coleções