Logotipo do repositório
 

Publicação:
Bond strength of Epiphany (TM) Sealer combined with different adhesive systems photo-activated with LED and QTH

dc.contributor.authorMinto, A. M. P.
dc.contributor.authorBandeca, Matheus Coelho [UNESP]
dc.contributor.authorBorges, A. H.
dc.contributor.authorNadalin, M. R.
dc.contributor.authorThome, L. H. C.
dc.contributor.institutionUniv Franca
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniv Cuiaba
dc.contributor.institutionUniv Ribeirao Preto
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2014-05-20T13:47:11Z
dc.date.available2014-05-20T13:47:11Z
dc.date.issued2009-08-01
dc.description.abstractThe Epiphany (TM) Sealer is a new dual-curing resin-based sealer and has been introduced as an alternative to gutta-percha and traditional root canal sealers. The canal filling is claimed to create a seal with the dentinal tubules within the root canal system producing a 'monoblock' effect between the sealer and dentinal tubules. Therefore, considering the possibility to incorporate the others adhesive systems, it is important to study the bond strength of the resulting cement. Forty-eight root mandibular canines were sectioned 8-mm below CEJ. The dentine discs were prepared using a tapered diamond bur and irrigated with 1% NaOCl and 17% EDTA. Previous the application Epiphany (TM) Sealer, the Epiphany (TM) Primer, AdheSE, and One Up Bond F were applied to the root canal walls. The LED and QTH (Quartz Tungsten Halogen) were used to photo-activation during 45 s with power density of 400 and 720 mW/cm(2), respectively. The specimens were performed on a universal testing machine at a cross-head speed of 1 mm/min until bond failure occurred. The force was recorded and the debonding values were used to calculate Push-out bond strength. The analysis of variance (ANOVA) and Tukey's post-hoc tests showed significant statistical differences (P < 0.05) to Epiphany (TM) Sealer/Epiphany (TM) Primer/QTH and EpiphanyTM Sealer/AdheSE/QTH, which had the highest mean values of bond strength. The efficiency of resin-based filling materials are dependent the type of light curing unit used including the power density, the polymerization characteristics of these resin-based filling materials, depending on the primer/adhesive used.en
dc.description.affiliationUniv Franca, BR-14404600 Franca, SP, Brazil
dc.description.affiliationUniv São Paulo State UNESP, Araraquara Sch Dent, Dept Restorat Dent, BR-14801903 Araraquara, SP, Brazil
dc.description.affiliationUniv Cuiaba, Dept Endodont, BR-78065700 Cuiaba, MT, Brazil
dc.description.affiliationUniv Ribeirao Preto, BR-14096900 Ribeirao Preto, SP, Brazil
dc.description.affiliationUniv São Paulo, Dept Restorat Dent, BR-14040904 Ribeirao Preto, Brazil
dc.description.affiliationUnespUniv São Paulo State UNESP, Araraquara Sch Dent, Dept Restorat Dent, BR-14801903 Araraquara, SP, Brazil
dc.format.extent1872-1876
dc.identifierhttp://dx.doi.org/10.1134/S1054660X09150304
dc.identifier.citationLaser Physics. New York: Maik Nauka/interperiodica/springer, v. 19, n. 8, p. 1872-1876, 2009.
dc.identifier.doi10.1134/S1054660X09150304
dc.identifier.issn1054-660X
dc.identifier.urihttp://hdl.handle.net/11449/16762
dc.identifier.wosWOS:000269012800058
dc.language.isoeng
dc.publisherMaik Nauka/interperiodica/springer
dc.relation.ispartofLaser Physics
dc.relation.ispartofjcr1.158
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.titleBond strength of Epiphany (TM) Sealer combined with different adhesive systems photo-activated with LED and QTHen
dc.typeArtigopt
dcterms.licensehttp://www.springer.com/open+access/authors+rights?SGWID=0-176704-12-683201-0
dcterms.rightsHolderMaik Nauka/interperiodica/springer
dspace.entity.typePublication
relation.isDepartmentOfPublication901124bf-5736-4432-b057-7c29dec84b50
relation.isDepartmentOfPublication.latestForDiscovery901124bf-5736-4432-b057-7c29dec84b50
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentOdontologia Restauradora - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: