Publicação: Influência da angulação e desajuste vertical na avaliação de microdeformações ao redor de implantes
dc.contributor.author | Rodrigues, Vinícius Anéas [UNESP] | |
dc.contributor.author | Tribst, João Paulo Mendes [UNESP] | |
dc.contributor.author | Santis, Leandro Ruivo de [UNESP] | |
dc.contributor.author | Lima, Dimas Renó de [UNESP] | |
dc.contributor.author | Nishioka, Renato Sussumu [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2018-12-11T17:34:17Z | |
dc.date.available | 2018-12-11T17:34:17Z | |
dc.date.issued | 2017-01-01 | |
dc.description.abstract | Objective: This in vitro study was to evaluate micro strains around of implant, under the influence of angulations and vertical misfit in three-element implant-supported fixed partial dentures during axial loading by using strain gauge analysis. Material and Methods: Three external hexagon implants with straight configuration and three external hexagon implants with angled (17°) configuration were inserted into two polyurethane blocks. To measure micro strain, four strain gauges were bonded onto the surface of each block. Plastic copings were adapted to a standard wax pattern and cast. An axial load of 30 kgf was applied on the center of each implant for 10 seconds, using a load application device. The vertical misfit was measured at six different points by using a stereo microscope with 100-X magnification. Results: The results showed that the values for different implant angulations were significant (P = 0.0086). The Pearson’s correlation test between micro-strain and vertical misfit revealed no correlation between angled configuration (P = 0.891) and straight configuration (P = 0.568). Conclusion: The micro strain was higher for angled implants; no correlation was found between the vertical misfit and the strain values. | en |
dc.description.affiliation | São Paulo State University (Unesp) Institute of Science and Technology Department of Dental Materials and Prosthodontics | |
dc.description.affiliation | São Paulo State University (Unesp) Institute of Science and Technology Department of Social and Pediatric Dentistry | |
dc.description.affiliationUnesp | São Paulo State University (Unesp) Institute of Science and Technology Department of Dental Materials and Prosthodontics | |
dc.description.affiliationUnesp | São Paulo State University (Unesp) Institute of Science and Technology Department of Social and Pediatric Dentistry | |
dc.format.extent | 32-39 | |
dc.identifier | http://dx.doi.org/10.14295/bds.2017.v20i1.1311 | |
dc.identifier.citation | Brazilian Dental Science, v. 20, n. 1, p. 32-39, 2017. | |
dc.identifier.doi | 10.14295/bds.2017.v20i1.1311 | |
dc.identifier.issn | 2178-6011 | |
dc.identifier.orcid | 0000-0002-1458-601X | |
dc.identifier.scopus | 2-s2.0-85029870955 | |
dc.identifier.uri | http://hdl.handle.net/11449/179225 | |
dc.language.iso | eng | |
dc.relation.ispartof | Brazilian Dental Science | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Scopus | |
dc.subject | Biomechanics | |
dc.subject | Dental implants | |
dc.subject | Dental prosthesis | |
dc.title | Influência da angulação e desajuste vertical na avaliação de microdeformações ao redor de implantes | pt |
dc.title.alternative | Influence of angulation and vertical misfit in the evaluation of micro-deformations around implants | en |
dc.type | Artigo | |
dspace.entity.type | Publication | |
unesp.author.orcid | 0000-0002-1458-601X[5] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campos | pt |
unesp.department | Materiais Odontológicos e Prótese - ICT | pt |
unesp.department | Odontologia Social e Clínica Infantil - ICT | pt |