Logotipo do repositório
 

Publicação:
Influência da angulação e desajuste vertical na avaliação de microdeformações ao redor de implantes

dc.contributor.authorRodrigues, Vinícius Anéas [UNESP]
dc.contributor.authorTribst, João Paulo Mendes [UNESP]
dc.contributor.authorSantis, Leandro Ruivo de [UNESP]
dc.contributor.authorLima, Dimas Renó de [UNESP]
dc.contributor.authorNishioka, Renato Sussumu [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T17:34:17Z
dc.date.available2018-12-11T17:34:17Z
dc.date.issued2017-01-01
dc.description.abstractObjective: This in vitro study was to evaluate micro strains around of implant, under the influence of angulations and vertical misfit in three-element implant-supported fixed partial dentures during axial loading by using strain gauge analysis. Material and Methods: Three external hexagon implants with straight configuration and three external hexagon implants with angled (17°) configuration were inserted into two polyurethane blocks. To measure micro strain, four strain gauges were bonded onto the surface of each block. Plastic copings were adapted to a standard wax pattern and cast. An axial load of 30 kgf was applied on the center of each implant for 10 seconds, using a load application device. The vertical misfit was measured at six different points by using a stereo microscope with 100-X magnification. Results: The results showed that the values for different implant angulations were significant (P = 0.0086). The Pearson’s correlation test between micro-strain and vertical misfit revealed no correlation between angled configuration (P = 0.891) and straight configuration (P = 0.568). Conclusion: The micro strain was higher for angled implants; no correlation was found between the vertical misfit and the strain values.en
dc.description.affiliationSão Paulo State University (Unesp) Institute of Science and Technology Department of Dental Materials and Prosthodontics
dc.description.affiliationSão Paulo State University (Unesp) Institute of Science and Technology Department of Social and Pediatric Dentistry
dc.description.affiliationUnespSão Paulo State University (Unesp) Institute of Science and Technology Department of Dental Materials and Prosthodontics
dc.description.affiliationUnespSão Paulo State University (Unesp) Institute of Science and Technology Department of Social and Pediatric Dentistry
dc.format.extent32-39
dc.identifierhttp://dx.doi.org/10.14295/bds.2017.v20i1.1311
dc.identifier.citationBrazilian Dental Science, v. 20, n. 1, p. 32-39, 2017.
dc.identifier.doi10.14295/bds.2017.v20i1.1311
dc.identifier.issn2178-6011
dc.identifier.orcid0000-0002-1458-601X
dc.identifier.scopus2-s2.0-85029870955
dc.identifier.urihttp://hdl.handle.net/11449/179225
dc.language.isoeng
dc.relation.ispartofBrazilian Dental Science
dc.rights.accessRightsAcesso restrito
dc.sourceScopus
dc.subjectBiomechanics
dc.subjectDental implants
dc.subjectDental prosthesis
dc.titleInfluência da angulação e desajuste vertical na avaliação de microdeformações ao redor de implantespt
dc.title.alternativeInfluence of angulation and vertical misfit in the evaluation of micro-deformations around implantsen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.orcid0000-0002-1458-601X[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.departmentMateriais Odontológicos e Prótese - ICTpt
unesp.departmentOdontologia Social e Clínica Infantil - ICTpt

Arquivos