Logo do repositório

SYSTEMIC EFFECTS RELATED TO THE USE OF 1% CYCLOPENTOLATE HYDROCHLORIDE EYE DROPS IN REFRACTOMETRY IN CATS

dc.contributor.authorda Silveira, Camila P.B. [UNESP]
dc.contributor.authorPiso, Dunia Y.T.
dc.contributor.authorBarros Sobrinho, Alexandre A.F. [UNESP]
dc.contributor.authorCrivelaro, Roberta M. [UNESP]
dc.contributor.authorAbreu, Thais G.M. [UNESP]
dc.contributor.authorFilezio, Marcella R. [UNESP]
dc.contributor.authorAldrovani, Marcela [UNESP]
dc.contributor.authorLaus, José L. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionUCC Ibagué
dc.date.accessioned2025-04-29T18:35:46Z
dc.date.issued2024-12-01
dc.description.abstractIn veterinary medicine, 1% Cyclopentolate hydrochloride (CP) has emerged as an intermediate-term cycloplegic and mydriatic agent. This study evaluated the pupillary dilation time and systemic effects related to the use of 1% CP eye drops in cats. Fifteen cats, aged 1 to 6 years and weighing 2.5 to 7 kg, were included in the study. After receiving written consent from the owners, each cat was administered two drops of 1% Cyclopentolate, 10 minutes apart, into both eyes. Data on pupil dilation, systemic symptoms, and behavioral changes were collected and analyzed using frequency and descriptive statistics. Pupillary dilation was observed 30 minutes after administering the second drop of 1% CP. The duration of pupillary dilation was 36 hours for 26.6% of the eyes, 48 hours for 53.4%, and 60 hours for 20%. Within the first hour after medication administration, seven cats exhibited episodes of salivation and vomiting, and four displayed behavioral changes, including aggressiveness and increased vocalization. Results suggest that 1% CP eye drops cause mydriasis for at least 36 hours and can lead to temporary adverse effects on the gastrointestinal and nervous systems.en
dc.description.affiliationSão Paulo State University (Unesp) School of Agricultural and Veterinarian Sciences Ophthalmology Unit Department of Small Animal Medicine and Surgery, SP
dc.description.affiliationCooperative University of Colombia UCC Ibagué
dc.description.affiliationUnespSão Paulo State University (Unesp) School of Agricultural and Veterinarian Sciences Ophthalmology Unit Department of Small Animal Medicine and Surgery, SP
dc.description.sponsorshipUniversidade Estadual Paulista
dc.format.extent546-555
dc.identifierhttp://dx.doi.org/10.2478/acve-2024-0038
dc.identifier.citationActa Veterinaria, v. 74, n. 3, p. 546-555, 2024.
dc.identifier.doi10.2478/acve-2024-0038
dc.identifier.issn1820-7448
dc.identifier.issn0567-8315
dc.identifier.scopus2-s2.0-85213398182
dc.identifier.urihttps://hdl.handle.net/11449/297955
dc.language.isoeng
dc.relation.ispartofActa Veterinaria
dc.sourceScopus
dc.subjectcyclopentolate
dc.subjectcycloplegic
dc.subjectfeline
dc.subjectmydriatic
dc.subjecttoxicity
dc.titleSYSTEMIC EFFECTS RELATED TO THE USE OF 1% CYCLOPENTOLATE HYDROCHLORIDE EYE DROPS IN REFRACTOMETRY IN CATSen
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublication3d807254-e442-45e5-a80b-0f6bf3a26e48
relation.isOrgUnitOfPublication.latestForDiscovery3d807254-e442-45e5-a80b-0f6bf3a26e48
unesp.author.orcid0000-0002-9972-0512[1]
unesp.author.orcid0000-0002-2642-7227[2]
unesp.author.orcid0000-0003-3796-1481[3]
unesp.author.orcid0000-0002-4521-8738[4]
unesp.author.orcid0000-0002-1777-5190[5]
unesp.author.orcid0000-0002-4256-1557[6]
unesp.author.orcid0000-0002-5734-3042[7]
unesp.author.orcid0000-0003-1932-8818[8]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Ciências Agrárias e Veterinárias, Jaboticabalpt

Arquivos