dc.description.abstractIncremental tests are commonly used to predict metabolic responses during square-wave mode exercises. However, in some cases the predicted and observed results may be not similar. Main objective: To verify the hypothesis that, at certain intensities in the severe domain, VO2 determined during the incremental test is lower than that observed at these workloads using the square-wave test. Methodological proceedings: Eight physically active males (21.5 ± 4 years, 73.7 ± 5.3 kg and 180.8 ± 4.1 cm) performed: 1) an incremental test on cycle ergometer to determine the VO2 of the intensities (VO2INC); 2) a square-wave test at three severe intensities (Light (L), Medium (M) and Heavy (H) to determine the critical power (CP) and to compare the VO2 (VO2RET) observed with the VO2INC;3) a square-wave test at CP intensity to compare the time response of VO2 with P, M and L, at four different sample times. Results: The VO2INCat L intensity underestimated the VO2RET(3.2 ± 0.5 vs. 3.8 ± 0.6 l.min-1). No differences were observed at the other intensities (M: 3.5 ± 0.5 vs. 3.6 ± 0.5 l.min-1; H: 3.7 ± 0.5 vs. 3.4 ± 0.6 l.min-1; CP: 2.7 ± 0.5 vs. 3.0 ± 0.6 l.min-1). The VO2 at CP was lower at all times, exhibited a steady state and did not achieve VO2max. Initially, at L intensity, the VO2 was smaller than its pairs. However, at the last sample time, it achieved VO2max and became equal to the other severe intensities. Conclusion: The incremental test underestimates the VO2 observed at lighter intensities within the severe domain.en
dc.description.affiliationUniversidade Estadual Paulista 'Julio de Mesquita Filho', Campus de Rio Claro
dc.description.affiliationInstituto de Biociências Departamento de Educação Física
dc.description.affiliationNúcleo de Atividade Física Esporte Saúde NAFES
dc.description.affiliationUnespUniversidade Estadual Paulista 'Julio de Mesquita Filho', Campus de Rio Claro
dc.format.extent289-293
dc.identifierhttp://dx.doi.org/10.5007/1980-0037.2008v10n3p289
dc.identifier.citationRevista Brasileira de Cineantropometria e Desempenho Humano, v. 10, n. 3, p. 289-293, 2008.
dc.identifier.doi10.5007/1980-0037.2008v10n3p289
dc.identifier.issn1415-8426
dc.identifier.issn1980-0037
dc.identifier.scopus2-s2.0-84893839177
dc.identifier.urihttp://hdl.handle.net/11449/232233
dc.language.isoeng
dc.language.isopor
dc.relation.ispartofRevista Brasileira de Cineantropometria e Desempenho Humano
dc.sourceScopus
dc.subjectConstant power
dc.subjectOxygen uptake
dc.subjectProgressive test
dc.subjectSevere domain
dc.titleConsumo de oxigênio no domínio de intensidade severo durante teste incremental e retangularpt
dc.title.alternativeOxygen consumption in the severe exercise intensity domain during incremental and square-wave test modesen
dc.typeArtigo
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Biociências, Rio Claropt
unesp.departmentEducação Física - IBpt

Arquivos