Logo do repositório

Análise biomecânica de pinos de fibra de vidro em diferentes quantidades de remanescentes dentários: estudo através do método de elementos finitos tridimensionais

dc.contributor.advisorFellippo, Ramos Verri [UNESP]
dc.contributor.authorOliveira, Vitor Galvão [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2023-02-06T12:03:53Z
dc.date.available2023-02-06T12:03:53Z
dc.date.issued2022-12-07
dc.description.abstractEste estudo analisou a distribuição de tensões gerada por cargas oclusais axiais e obliquas sobre próteses fixas unitárias com coroas metal free em zircônia sobre dentes despolpados, variando-se a quantidade de remanescente e o sistema de pino (convencional e Splendor-SAP® - Simple Adjustable Post), através da análise dos elementos finitos tridimensionais. Foram confeccionados 6 modelos 3D contendo um bloco da região de pré-maxila com presença do elemento 21, subdivididos em ossos cortical e trabecular, simulando osso tipo III. Os modelos gerados foram exportados para o software ANSYS 19 (Southpointe, PA, USA) para discretização. Para cada modelo, 3 análises de força de 178N foram executadas sendo aplicadas 2 mm abaixo da borda incisal a 0°, 30° e 60° em relação ao longo eixo dentário. Foram gerados mapas de deslocamento (mm), tensão de von Mises (MPa), e tensão máxima principal (MPa). Os mapas de deslocamento e de tensão de von Mises não apresentaram diferenças significativas. Os mapas de tensão máxima principal mostraram que os modelos com Splendor-SAP® concentraram menos tensão de tração na cervical da coroa protética, área crítica do modelo. Além disso, o comportamento biomecânico, para ângulos maiores, foi mais favorável nos modelos com pinos Splendor-SAP®, sendo mais crítico o remanescente nos dentes tratados com pinos convencionais. Foi possível concluir que pinos Splendor-SAP® quando indicados, reduzem a influência negativa da perda coronária para a confecção de coroas protéticas e favorecem a distribuição de tensões, comparados aos pinos convencionais.pt
dc.description.abstractThis study analyzed the stress distribution generated by occlusal loads on single fixed prostheses with metal free zirconia crowns on pulpless teeth, varying the amount of remainder and the post system (conventional and Splendor-SAP® - Simple Adjustable Post), through the three-dimensional finite elements analysis. Six 3D models were made containing a block of the premaxilla region with the presence of element 21, simulating type III bone. The ANSYS 19 software (Southpointe, PA, USA) was used for discretization of the models. For each model, 3 force analyzes of 178N were performed being applied 2 mm below the incisal edge at 0°, 30° and 60° in relation to the long tooth axis. The von Mises stress and displacement maps did not show significant differences. The maximum principal stress maps showed that the models with Splendor-SAP® concentrated less tensile stress on the cervical of the prosthetic crown. In addition, the biomechanical behavior, for higher angles, was more favorable in models with Splendor-SAP® posts, with the remnant being more critical in teeth treated with conventional posts. Concluding that the Splendor-SAP®, when indicated, reduce the negative influence of coronary loss for the manufacture of prosthetic crowns and favor stress distribution, compared to conventional pins.en
dc.identifier.capes33004021073P5
dc.identifier.urihttp://hdl.handle.net/11449/239326
dc.language.isoeng
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso abertopt
dc.subjectCoroas (Odontologia) Técnica para retentor intrarradicularpt
dc.subjectAnálise de elementos finitospt
dc.subjectFenômenos biomecânicospt
dc.subjectFinite element analysisen
dc.titleAnálise biomecânica de pinos de fibra de vidro em diferentes quantidades de remanescentes dentários: estudo através do método de elementos finitos tridimensionaispt
dc.title.alternativeBiomechanical analysis of glass fiber posts in different amounts of remnants: study through the three-dimensional finite element methoden
dc.typeDissertação de mestradopt
dspace.entity.typePublication
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.embargoOnlinept
unesp.examinationboard.typeBanca públicapt
unesp.graduateProgramCiência Odontológica - FOApt
unesp.knowledgeAreaBiomateriaispt
unesp.researchAreaBioprodutos, biomateriais e nanobiomateriais: propriedades físicas, químicas e biológicaspt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
oliveira_vg_me_araca_int.pdf
Tamanho:
2.19 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
3.05 KB
Formato:
Item-specific license agreed upon to submission
Descrição: