Publicação: Determination of cadmium in river water samples by flame AAS after on-line preconcentration in mini-column packed with 2-aminothiazole-modified silica gel
dc.contributor.author | Alcântara, Ilton L. [UNESP] | |
dc.contributor.author | Roldan, Paulo S. [UNESP] | |
dc.contributor.author | Castro, Gustavo R. [UNESP] | |
dc.contributor.author | Moraes, Fabrício V. [UNESP] | |
dc.contributor.author | Silva, Fábio A. [UNESP] | |
dc.contributor.author | Padilha, Cilene C. F. [UNESP] | |
dc.contributor.author | Oliveira, Jorge D. [UNESP] | |
dc.contributor.author | Padilha, Pedro M. [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade Estadual do Maranhão (UEMA) | |
dc.date.accessioned | 2014-05-27T11:21:06Z | |
dc.date.available | 2014-05-27T11:21:06Z | |
dc.date.issued | 2004-07-01 | |
dc.description.abstract | A rapid and sensitive method was developed to determine trace levels of Cd2+ ions in an aqueous medium by flame atomic absorption spectrometry, using on-line preconcentration in a mini-column packed with 100 mg of 2-aminothiazol modified silica gel (SiAT). The Cd2+ ions were sorbed at pH 5.0. The preconcentrated Cd2+ ions were directly eluted from the column to the spectrometer's nebulizer-burner system using 100 μL of 2 mol L-1 hydrochloric acid. A retention efficiency of over 95% was achieved. The enrichment factor (calculated as the ratio of slopes of the calibration graphs) obtained with preconcentrations in a mini-column packed with SiAT (A = -1.3 × 10-3 + 1.8 × 10-3 [Cd2+]) and without preconcentrations (A = 4 × 10-5 + 3.5 × 10-3[Cd2+]), was 51 and the detection limit calculated was 0.38 μg L-1. The preconcentration procedure was applied to determine trace levels of Cd in river water samples. The optimum preconcentration conditions are discussed herein. | en |
dc.description.affiliation | Instituto de Química Departamento de Quimica Analitica UNESP, P. O. Box 355, 14800-900, Araraquara, SP | |
dc.description.affiliation | Instituto de Biociência Departamento de Quimica e Bioquimica UNESP, P. O. Box 510, 18618-000, Botucatu, SP | |
dc.description.affiliation | Instituto de Biociências Departamento de Fisica e Biofisica UNESP, P. O. Box 510, 18618-000, Botucatu, SP | |
dc.description.affiliation | Universidade Estadual do Maranhao CESI, 65901-480, Imperatriz, MA | |
dc.description.affiliationUnesp | Instituto de Química Departamento de Quimica Analitica UNESP, P. O. Box 355, 14800-900, Araraquara, SP | |
dc.description.affiliationUnesp | Instituto de Biociência Departamento de Quimica e Bioquimica UNESP, P. O. Box 510, 18618-000, Botucatu, SP | |
dc.description.affiliationUnesp | Instituto de Biociências Departamento de Fisica e Biofisica UNESP, P. O. Box 510, 18618-000, Botucatu, SP | |
dc.format.extent | 1029-1032 | |
dc.identifier | http://dx.doi.org/10.2116/analsci.20.1029 | |
dc.identifier.citation | Analytical Sciences, v. 20, n. 7, p. 1029-1032, 2004. | |
dc.identifier.doi | 10.2116/analsci.20.1029 | |
dc.identifier.file | 2-s2.0-3542992106.pdf | |
dc.identifier.issn | 0910-6340 | |
dc.identifier.lattes | 6981448637456391 | |
dc.identifier.orcid | 0000-0003-4179-0574 | |
dc.identifier.scopus | 2-s2.0-3542992106 | |
dc.identifier.uri | http://hdl.handle.net/11449/67792 | |
dc.identifier.wos | WOS:000222697500007 | |
dc.language.iso | eng | |
dc.relation.ispartof | Analytical Sciences | |
dc.relation.ispartofjcr | 1.355 | |
dc.relation.ispartofsjr | 0,424 | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Scopus | |
dc.subject | 2 aminothiazole derivative | |
dc.subject | cadmium | |
dc.subject | hydrochloric acid | |
dc.subject | river water | |
dc.subject | silica gel | |
dc.subject | adsorption | |
dc.subject | aqueous solution | |
dc.subject | atomic absorption spectrometry | |
dc.subject | calibration | |
dc.subject | combustion | |
dc.subject | concentration (parameters) | |
dc.subject | elution | |
dc.subject | flame atomic absorption spectrometry | |
dc.subject | nebulizer | |
dc.subject | online system | |
dc.subject | pH | |
dc.subject | sensitivity and specificity | |
dc.subject | water sampling | |
dc.subject | Cadmium | |
dc.subject | Calibration | |
dc.subject | Hydrochloric Acid | |
dc.subject | Hydrogen-Ion Concentration | |
dc.subject | Ions | |
dc.subject | Models, Chemical | |
dc.subject | Silicon Dioxide | |
dc.subject | Spectrophotometry | |
dc.subject | Spectrophotometry, Atomic | |
dc.subject | Spectrophotometry, Infrared | |
dc.subject | Thiazoles | |
dc.subject | Time Factors | |
dc.subject | Water | |
dc.title | Determination of cadmium in river water samples by flame AAS after on-line preconcentration in mini-column packed with 2-aminothiazole-modified silica gel | en |
dc.type | Artigo | |
dcterms.license | http://www.jsac.or.jp/analsci/info.php/about.html | |
dspace.entity.type | Publication | |
unesp.author.lattes | 6981448637456391[6] | |
unesp.author.orcid | 0000-0003-4179-0574[8] | |
unesp.author.orcid | 0000-0003-4179-0574[6] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Biociências, Botucatu | pt |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Física e Biofísica - IBB | pt |
unesp.department | Química e Bioquímica - IBB | pt |
unesp.department | Química Analítica - IQAR | pt |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- 2-s2.0-3542992106.pdf
- Tamanho:
- 104.9 KB
- Formato:
- Adobe Portable Document Format