Logotipo do repositório

Propriedades ópticas e investigação teórico-experimental de sistemas luminescentes derivados do copolímero P123 por tratamentos térmico e hidrotermal

dc.contributor.advisorBarreiro, Luiz Antonio
dc.contributor.authorCarmo, Ana Paula do
dc.contributor.committeeMemberBarreiro, Luiz Antonio
dc.contributor.committeeMemberSantos, Ricardo Paupitz Barbosa dos
dc.contributor.committeeMemberMesquita, Alexandre
dc.contributor.committeeMemberFaria Júnior, Antônio Carlos Amaro
dc.contributor.committeeMemberBassi, Ana Lúcia
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)pt
dc.date.accessioned2026-09-15T14:34:21Z
dc.date.issued2026-07-31
dc.description.abstractNeste trabalho investigaram-se as relações entre as condições de processamento, a organização estrutural e as propriedades ópticas de sistemas luminescentes derivados do copolímero tribloco P123. Foram consideradas duas rotas principais de preparação: tratamento térmico do P123 seguido de dispersão em etanol e tratamento hidrotermal de sistemas contendo P123 e polietilenoglicol (PEG). A influência da temperatura, do tempo de tratamento, da concentração e do volume foi avaliada por espectroscopia de fotoluminescência, absorção no ultravioleta-visível (UV-Vis) e espectroscopia Raman. A caracterização experimental foi complementada por cálculos de estrutura molecular e eletrônica baseados na Teoria do Funcional da Densidade (DFT) e em DFTB+. Os espectros de fotoluminescência apresentaram bandas largas predominantemente na região azul do espectro visível, com intensidade e posição dependentes das condições de processamento e do comprimento de onda de excitação. Para o P123 tratado termicamente e posteriormente disperso em etanol, a intensidade de emissão aumentou com a temperatura até aproximadamente 250 ◦C, diminuindo para temperaturas superiores. Entre as condições comparadas, a amostra preparada a 250◦C durante 1 h, com concentração de 15 mg/mL, apresentou a maior intensidade de emissão. Nos sistemas submetidos a tratamento hidrotermal a 160◦C, verificou-se que o próprio PEG apresenta emissão na região azul, evidenciando sua contribuição para a resposta óptica das soluções P123/PEG. Os resultados Raman indicaram modificações conformacionais e estruturais associadas ao processamento, enquanto os espectros UV-Vis evidenciaram alterações nas regiões de absorção. Os cálculos de estrutura eletrônica forneceram informações complementares sobre a distribuição de densidade eletrônica e os estados moleculares envolvidos nas transições ópticas. Em conjunto, os resultados demonstram que as condições de processamento modificam significativamente a estrutura e a resposta óptica dos sistemas investigados e são compatíveis com a formação de diferentes estados emissores e de espécies ou domínios carbonáceos luminescentes derivados do P123. Entretanto, as técnicas empregadas não permitem estabelecer de maneira inequívoca a formação de pontos quânticos de carbono nem determinar diretamente sua morfologia e distribuição de tamanho, sendo necessárias caracterizações estruturais complementares para essa identificação.pt
dc.description.abstractThis work investigates the relationships between processing conditions, structural organization, and the optical properties of luminescent systems derived from the P123 triblock copolymer. Two main preparation routes were considered: thermal treatment of P123 followed by dispersion in ethanol, and hydrothermal treatment of systems containing P123 and polyethylene glycol (PEG). The effects of temperature, treatment time, concentration, and volume were investigated by photoluminescence spectroscopy, ultraviolet-visible (UV-Vis) absorption spectroscopy, and Raman spectroscopy. The experimental characterization was complemented by molecular and electronic structure calculations based on Density Functional Theory (DFT) and DFTB+. The photoluminescence spectra exhibited broad emission bands predominantly in the blue region of the visible spectrum, with intensities and spectral positions dependent on the processing conditions and excitation wavelength. For thermally treated P123 subsequently dispersed in ethanol, the emission intensity increased with temperature up to approximately 250 ◦C and decreased at higher temperatures. Among the conditions investigated, the sample prepared at 250◦C for 1 h at a concentration of 15 mg/mL exhibited the highest emission intensity. For systems hydrothermally treated at 160◦C, PEG itself was found to exhibit blue emission, demonstrating its contribution to the optical response of the P123/PEG solutions. Raman spectroscopy indicated conformational and structural modifications induced by processing, whereas UV-Vis spectra revealed changes in the absorption regions. Electronic-structure calculations provided complementary information on the electron-density distribution and molecular states involved in the optical transitions. Overall, the results demonstrate that the processing conditions significantly modify the structure and optical response of the investigated systems and are consistent with the formation of different emissive states and luminescent carbonaceous species or domains derived from P123. However, the techniques employed in this work do not allow the unequivocal identification of carbon quantum dots or the direct determination of their morphology and size distribution; additional structural characterization is therefore required for such an assignment.en
dc.identifier.capes33004137063P6
dc.identifier.citationCARMO, Ana Paula do. Propriedades ópticas e investigação teórico-experimental de sistemas luminescentes derivados do copolímero P123 por tratamentos térmico e hidrotermal. 2026. Doutorado (Tese em Física) — Instituto de Geociências e Ciências Exatas, Universidade Estadual Paulista (UNESP), Rio Claro, 2026.
dc.identifier.lattes0821381466357620
dc.identifier.lattes8837845109364729
dc.identifier.lattes8837845109364729
dc.identifier.lattes5313696806283523
dc.identifier.lattes2835864951583089
dc.identifier.orcid0000-0002-2144-1775
dc.identifier.orcid0000-0003-4637-3403
dc.identifier.orcid0000-0003-4637-3403
dc.identifier.orcid0000-0003-1254-6353
dc.identifier.orcid0000-0001-8524-0959
dc.identifier.urihttps://hdl.handle.net/11449/331749
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (UNESP)pt
dc.rights.accessRightsAcesso abertopt
dc.subjectFotoluminescênciapt
dc.subjectTratamento hidrotermalpt
dc.subjectEspectroscopia Ramanpt
dc.subjectTeoria do Funcional da Densidade (DFT)pt
dc.subjectPhotoluminescenceen
dc.subjectHydrothermal treatmenten
dc.subjectRaman spectroscopyen
dc.subjectOptical propertiesen
dc.subjectElectronic structureen
dc.titlePropriedades ópticas e investigação teórico-experimental de sistemas luminescentes derivados do copolímero P123 por tratamentos térmico e hidrotermalpt
dc.title.alternativeOptical properties and theoretical-experimental investigation of luminescent systems derived from p123 copolymer through thermal and hydrothermal treatmentsen
dc.typeTese de doutoradopt
dspace.entity.typePublication
relation.isAdvisorOfPublication61a74b37-3318-433c-b301-72fe71c7eda6
relation.isAdvisorOfPublication.latestForDiscovery61a74b37-3318-433c-b301-72fe71c7eda6
relation.isAuthorOfPublication1209808e-26a0-46af-8b54-d59e557a4839
relation.isAuthorOfPublication.latestForDiscovery1209808e-26a0-46af-8b54-d59e557a4839
relation.isCommitteeMemberOfPublication61a74b37-3318-433c-b301-72fe71c7eda6
relation.isCommitteeMemberOfPublication2b4df2ca-bd85-44af-a8a5-aa8061c834a8
relation.isCommitteeMemberOfPublicationacc79489-46a9-406d-8678-516472213c3b
relation.isCommitteeMemberOfPublication.latestForDiscovery61a74b37-3318-433c-b301-72fe71c7eda6
relation.isCommitteeMemberOfPublication.latestForDiscovery2b4df2ca-bd85-44af-a8a5-aa8061c834a8
relation.isCommitteeMemberOfPublication.latestForDiscoveryacc79489-46a9-406d-8678-516472213c3b
relation.isGradProgramOfPublication9c2807cc-a873-4c66-ba2b-2e0d4b6ef373
relation.isGradProgramOfPublication.latestForDiscovery9c2807cc-a873-4c66-ba2b-2e0d4b6ef373
relation.isOrgUnitOfPublication4763ec56-704e-41e0-9685-b5bef5946feb
relation.isOrgUnitOfPublication.latestForDiscovery4763ec56-704e-41e0-9685-b5bef5946feb
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Geociências e Ciências Exatas, Rio Claropt
unesp.examinationboard.typeBanca públicapt
unesp.graduateProgramFísica - IGCEpt
unesp.knowledgeAreaFísica aplicadapt
unesp.researchAreaNovos materiais.pt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
carmo_ap_dr_rcla.pdf
Tamanho:
3,67 MB
Formato:
Adobe Portable Document Format