Logotipo do repositório
 

Publicação:
Evaluation of sample treatment for the simultaneous flow injection hydride generation and determination of As, Bi, Sb and Se by GRAS

dc.contributor.authorFreschi, C. D.
dc.contributor.authorFreschi, GPG
dc.contributor.authorNeto, JAG
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T15:29:50Z
dc.date.available2014-05-20T15:29:50Z
dc.date.issued2004-05-01
dc.description.abstractA new method was developed for the simultaneous determination of As, Bi, Sb, and Se by flow injection hydride generation graphite furnace atomic absorption spectrometry. An alternative two-step sample treatment procedure was used. The sample was heated (80degreesC) for 10 min in 6 M HCl to reduce Se(VI) to Se(IV), followed by the addition of 1% (m/v) thiourea solution to reduce arsenic and antimony from the pentavalent to the trivalent states.With this procedure, all analytes were converted to their most favorable and sensitive oxidation states to generate the corresponding hydrides. The pre-treated sample solution was then processed in the flow system for in situ trapping and atomization in a graphite tube coated with iridium. The impermanent modifier remained stable up to 300 firings and new coating out significant were possible wit changes in the analytical performance.The accuracy was checked for As, Bi, Sb, and Se determination in water standard reference materials NIST 1640 and 1643d and the results were in agreement with the certified values at a 95% confidence level. Good recoveries (94-104%.) of spiked mineral waters and synthetic As(V), Sb(Ill), mixtures of As(Ill), Sb(V), Se(VI), and Se(IV) were also found. Calculated characteristic masses were 32 mug As, 79 mug Bi, 35 mug Sb, and 130 pg Se, and the corresponding limits of detection were 0.06, 0.16, 0.19, and 0.59 mug L-1, respectively. The repeatability for a typical solution containing 5 mug L-1 As, Bi, Sb, and Se was in the 1-3% range.en
dc.description.affiliationUniv Estadual Paulista, Inst Quim, BR-14801970 Araraquara, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Inst Quim, BR-14801970 Araraquara, SP, Brazil
dc.format.extent133-139
dc.identifier.citationAtomic Spectroscopy. Shelton: Perkin-elmer Corp, v. 25, n. 3, p. 133-139, 2004.
dc.identifier.issn0195-5373
dc.identifier.urihttp://hdl.handle.net/11449/39328
dc.identifier.wosWOS:000222413900004
dc.language.isoeng
dc.publisherPerkin-elmer Corp
dc.relation.ispartofAtomic Spectroscopy
dc.relation.ispartofjcr1.123
dc.relation.ispartofsjr0,327
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.titleEvaluation of sample treatment for the simultaneous flow injection hydride generation and determination of As, Bi, Sb and Se by GRASen
dc.typeArtigopt
dcterms.rightsHolderPerkin-elmer Corp
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt