Publicação: Fracture load of complete-arch implant-supported prostheses reinforced with nylon-silica mesh: An in vitro study
dc.contributor.author | Gonçalves, Fernanda de Cássia Papaiz | |
dc.contributor.author | Amaral, Marina | |
dc.contributor.author | Borges, Alexandre Luiz Souto [UNESP] | |
dc.contributor.author | Gonçalves, Luiz Fernando Martins | |
dc.contributor.author | Paes-Junior, Tarcisio José de Arruda [UNESP] | |
dc.contributor.institution | São José dos Campos | |
dc.contributor.institution | University of Taubaté (UNITAU) | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2018-12-11T17:13:09Z | |
dc.date.available | 2018-12-11T17:13:09Z | |
dc.date.issued | 2018-04-01 | |
dc.description.abstract | Statement of problem: Complete-arch implant-supported prostheses without a framework have a high risk of failure: a straightforward and inexpensive reinforcement material, such as nylon mesh, could improve their longevity. Purpose: The purpose of this in vitro study was to evaluate a nylon-silica mesh compound on the fracture strength of acrylic resin and the fracture load of complete-arch implant-supported prostheses. Material and methods: Twenty-four complete mandibular arch implant-supported prostheses were divided into 2 groups according to cantilever length (molar and premolar) and subdivided into another 2 subgroups according to the presence or absence of reinforcing mesh. The specimens were submitted to a maximum load-to-fracture test in a universal testing machine, with a 100-N load cell, a 2 mm/min crosshead speed, and a spherical metal tip diameter of 4 mm at different points (molar and premolar). These were submitted to 1-way analysis of variance for repeated measurement and the post hoc Tukey multiple comparison test (α=.05). Results: The mean maximum load ±standard deviation for the molar group was 393.4 ±95.0 N with reinforcement and 305.4 ±76.3 N without reinforcement (P=.02); and for the premolar group was 1083.3 ±283.7 N with reinforcement and 605.3 ±90.5 N without reinforcement (P=.001). Conclusions: Reinforcement with nylon mesh increased the mean maximum load of implant-supported complete-arch prostheses at both cantilever lengths. The cantilever to the premolar (5 mm) presented the highest maximum load values to fracture. | en |
dc.description.affiliation | Postdoctoral Program Institute of Aeronautics Technology (ITA) São José dos Campos | |
dc.description.affiliation | Dental Prostheses Department of Dentistry University of Taubaté (UNITAU) | |
dc.description.affiliation | Associate Professor Department of Dental Materials and Prosthodontics São Paulo State University (UNESP) Institute of Science and Technology São José dos Campos | |
dc.description.affiliation | Researcher Engineering Applications Laboratory Institute of Aeronautics Technology (ITA) São José dos Campos | |
dc.description.affiliationUnesp | Associate Professor Department of Dental Materials and Prosthodontics São Paulo State University (UNESP) Institute of Science and Technology São José dos Campos | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorshipId | FAPESP: 2011/07334-6 | |
dc.format.extent | 606-610 | |
dc.identifier | http://dx.doi.org/10.1016/j.prosdent.2017.05.018 | |
dc.identifier.citation | Journal of Prosthetic Dentistry, v. 119, n. 4, p. 606-610, 2018. | |
dc.identifier.doi | 10.1016/j.prosdent.2017.05.018 | |
dc.identifier.file | 2-s2.0-85021898918.pdf | |
dc.identifier.issn | 0022-3913 | |
dc.identifier.scopus | 2-s2.0-85021898918 | |
dc.identifier.uri | http://hdl.handle.net/11449/174853 | |
dc.language.iso | eng | |
dc.relation.ispartof | Journal of Prosthetic Dentistry | |
dc.relation.ispartofsjr | 1,087 | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Scopus | |
dc.title | Fracture load of complete-arch implant-supported prostheses reinforced with nylon-silica mesh: An in vitro study | en |
dc.type | Artigo | |
dspace.entity.type | Publication | |
unesp.author.lattes | 6043459304176015[3] | |
unesp.author.orcid | 0000-0002-4301-2760[2] | |
unesp.author.orcid | 0000-0002-5707-7565[3] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campos | pt |
unesp.department | Materiais Odontológicos e Prótese - ICT | pt |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- 2-s2.0-85021898918.pdf
- Tamanho:
- 932.88 KB
- Formato:
- Adobe Portable Document Format
- Descrição: