Logotipo do repositório
 

Publicação:
Cross linked Poly (4-Vinylpyridine-Ethylene Glycol Dimethacrylate) Used for Preconcentration of Cd(II) and its Determination by Flow Injection Flame Atomic Absorption Spectrometry

dc.contributor.authorTeixeira Tarley, Cesar Ricardo
dc.contributor.authorBotteon Farias, Natalia Cristina
dc.contributor.authorLima, Giovana de Fatima
dc.contributor.authorOliveira, Fernanda Midori de
dc.contributor.authorBonfilio, Rudy [UNESP]
dc.contributor.authorDragunski, Douglas Cardoso
dc.contributor.authorClausen, Debora Nobile
dc.contributor.authorSegatelli, Mariana Gava
dc.contributor.institutionUniversidade Estadual de Londrina (UEL)
dc.contributor.institutionUniversidade Federal de Uberlândia (UFU)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Estadual do Oeste do Paraná (UNIOESTE)
dc.date.accessioned2014-12-03T13:08:53Z
dc.date.available2014-12-03T13:08:53Z
dc.date.issued2014-03-01
dc.description.abstractThe main purpose of this research was to synthesize crosslinked poly(4-vinylpyridine-ethylene glycol dimethacrylate) and evaluate its feasibility for highly sensitive and selective determination of Cd in water samples by using flow injection flame atomic absorption spectrometry. The crosslinked polymer, prepared by bulk polymerization, was characterized by FTIR spectrometry and scanning electron microscopy. The flow injection solid-phase method was based on preconcentration of 20.0 mL of sample through 100 mg of the polymer packed into a minicolumn at pH 8.25 using a flow rate of 6.0 mL/min, followed by elution with 1.0 M HNO3. The sample solution parameters influencing the preconcentration behavior of Cd ions, such as pH, buffer concentration, and flow rate, were simultaneously studied and optimized using? Doehlert matrix. Values of 0.10 mu g/L, 2.0-210 mu g/L, 32.3, 18/h, 9.7/min, and 0.62 mL were obtained for LOD, linear range, preconcentration factor, sample throughput, concentration efficiency, and consumption index, respectively. The effect of the presence of the inorganic cations Pb(II), U(IV), Co(II), Hg(II), Cu(II), As(III), Mg(II), Sb(III), Ni(II), Th(IV), Ba(II), and Ca(II) on the method was studied, and the preconcentration of Cd was observed to have no interference. The accuracy of the method was assessed by analysis of natural water samples using addition and recovery tests and inductively coupled plasma/MS as a reference technique, as well as by analysis of a standard reference material of trace elements in water.en
dc.description.affiliationUniv Estadual Londrina UEL, Dept Quim, Ctr Ciencias Exatas, BR-86050482 Londrina, PR, Brazil
dc.description.affiliationUniv Fed Uberlandia, Programa Posgrad Quim, BR-38400902 Uberlandia, MG, Brazil
dc.description.affiliationUNESP Univ Estadual Paulista, Fac Ciencias Farmaceut, BR-14801902 Araraquara, SP, Brazil
dc.description.affiliationUniv Estadual Oeste Parana Unioeste, BR-85900000 Toledo, PR, Brazil
dc.description.affiliationUnespUNESP Univ Estadual Paulista, Fac Ciencias Farmaceut, BR-14801902 Araraquara, SP, Brazil
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipINCT for Bioanalytics (Instituto Nacional de Ciencia e Tecnologia de Bioanalitica)
dc.format.extent605-611
dc.identifierhttp://dx.doi.org/10.5740/jaoacint.11-392
dc.identifier.citationJournal Of Aoac International. Gaithersburg: Aoac Int, v. 97, n. 2, p. 605-611, 2014.
dc.identifier.doi10.5740/jaoacint.11-392
dc.identifier.issn1060-3271
dc.identifier.urihttp://hdl.handle.net/11449/111681
dc.identifier.wosWOS:000334568300038
dc.language.isoeng
dc.publisherAoac Int
dc.relation.ispartofJournal of AOAC International
dc.relation.ispartofjcr1.087
dc.relation.ispartofsjr0,324
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.titleCross linked Poly (4-Vinylpyridine-Ethylene Glycol Dimethacrylate) Used for Preconcentration of Cd(II) and its Determination by Flow Injection Flame Atomic Absorption Spectrometryen
dc.typeArtigopt
dcterms.rightsHolderAoac Int
dspace.entity.typePublication
relation.isOrgUnitOfPublication95697b0b-8977-4af6-88d5-c29c80b5ee92
relation.isOrgUnitOfPublication.latestForDiscovery95697b0b-8977-4af6-88d5-c29c80b5ee92
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Ciências Farmacêuticas, Araraquarapt

Arquivos