Publicação: Stress distribution in implant-supported prosthesis with external and internal implant-abutment connections
dc.contributor.author | Goiato, Marcelo Coelho [UNESP] | |
dc.contributor.author | Pesqueira, Aldieris Alves [UNESP] | |
dc.contributor.author | Falcón-Antenucci, Rosse Mary [UNESP] | |
dc.contributor.author | Santos, Daniela Micheline dos [UNESP] | |
dc.contributor.author | Haddad, Marcela Filié [UNESP] | |
dc.contributor.author | Bannwart, Lisiane Cristina [UNESP] | |
dc.contributor.author | Moreno, Amália [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-27T11:28:37Z | |
dc.date.available | 2014-05-27T11:28:37Z | |
dc.date.issued | 2013-03-01 | |
dc.description.abstract | Objective. This study aimed to investigate the stress distribution in screwed implant-supported prostheses with different implant-abutment connections by using a photoelastic analysis. Materials and methods. Four photoelastic models were fabricated in PL-2 resin and divided according to the implant-abutment connection (external hexagon (EH) and Morse taper (MT) implants (3.75 × 11.5 mm)) and the number crowns (single and 3-unit piece). Models were positioned in a circular polariscope and 100-N axial and oblique (45) loading were applied in the occlusal surface of the crowns by using a universal testing machine. The stresses were photographically recorded and qualitatively analyzed using software (Adobe Photoshop). Results. Under axial loading, the MT implants exhibited a lower number of fringes for single-unit crowns than EH implants, whereas for a 3-unit piece the MT implants showed a higher number of fringes vs EH implants. The oblique loading increased the number of fringes for all groups. Conclusion. In conclusion, the MT implant-abutment connection reduced the amount of stress in single-unit crowns, for 3-unit piece crowns the amount of stress was lower using an external hexagon connection. The stress pattern was similar for all groups. Oblique loading promoted a higher stress concentration than axial loading. © Informa Healthcare. | en |
dc.description.affiliation | Department of Dental Materials and Prosthodontics UNESP-São Paulo State University-José Bonifácio São Paulo State University-UNESP, 1193, Vila Mendonça Araçatuba, Araçatuba, São Paulo - 16050-050 | |
dc.description.affiliationUnesp | Department of Dental Materials and Prosthodontics UNESP-São Paulo State University-José Bonifácio São Paulo State University-UNESP, 1193, Vila Mendonça Araçatuba, Araçatuba, São Paulo - 16050-050 | |
dc.format.extent | 283-288 | |
dc.identifier | http://dx.doi.org/10.3109/00016357.2012.672823 | |
dc.identifier.citation | Acta Odontologica Scandinavica, v. 71, n. 2, p. 283-288, 2013. | |
dc.identifier.doi | 10.3109/00016357.2012.672823 | |
dc.identifier.issn | 0001-6357 | |
dc.identifier.issn | 1502-3850 | |
dc.identifier.lattes | 9719883814872582 | |
dc.identifier.orcid | 0000-0002-3800-3050 | |
dc.identifier.scopus | 2-s2.0-84874494180 | |
dc.identifier.uri | http://hdl.handle.net/11449/74757 | |
dc.identifier.wos | WOS:000315413000001 | |
dc.language.iso | eng | |
dc.relation.ispartof | Acta Odontologica Scandinavica | |
dc.relation.ispartofjcr | 1.522 | |
dc.relation.ispartofsjr | 0,706 | |
dc.relation.ispartofsjr | 0,706 | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Scopus | |
dc.subject | Biomechanics | |
dc.subject | Dental implants | |
dc.subject | Fixed prosthesis | |
dc.subject | Photoelastic stress analysis | |
dc.subject | Screw retained | |
dc.subject | biomechanics | |
dc.subject | dental abutment | |
dc.subject | human | |
dc.subject | theoretical model | |
dc.subject | tooth implant | |
dc.subject | Dental Implant-Abutment Design | |
dc.subject | Dental Implants | |
dc.subject | Humans | |
dc.subject | Models, Theoretical | |
dc.title | Stress distribution in implant-supported prosthesis with external and internal implant-abutment connections | en |
dc.type | Artigo | pt |
dcterms.license | http://informahealthcare.com/userimages/ContentEditor/1255620309227/Copyright_And_Permissions.pdf | |
dspace.entity.type | Publication | |
relation.isDepartmentOfPublication | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isDepartmentOfPublication.latestForDiscovery | 5f53b343-da2a-4737-96ec-6e2389a6d704 | |
relation.isOrgUnitOfPublication | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
relation.isOrgUnitOfPublication.latestForDiscovery | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
unesp.author.lattes | 9719883814872582 | |
unesp.author.lattes | 2336450644149867[2] | |
unesp.author.orcid | 0000-0002-3800-3050[1] | |
unesp.author.orcid | 0000-0003-3020-5253[2] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatuba | pt |
unesp.department | Materiais odontológicos e Prótese - FOA | pt |