Publicação: Photoelastic analysis of forces generated by T-loop springs made with stainless steel or titanium-molybdenum alloy
dc.contributor.author | Martins Maia, Luiz Guilherme [UNESP] | |
dc.contributor.author | de Moraes Maia, Mila Leite | |
dc.contributor.author | Monini, Andre da Costa [UNESP] | |
dc.contributor.author | Vianna, Alexandre Protasio [UNESP] | |
dc.contributor.author | Gandini Júnior, Luiz Gonzaga [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade Federal de Sergipe (UFS) | |
dc.contributor.institution | St Louis Univ | |
dc.contributor.institution | Baylor Coll Dent | |
dc.date.accessioned | 2014-05-20T15:33:11Z | |
dc.date.available | 2014-05-20T15:33:11Z | |
dc.date.issued | 2011-09-01 | |
dc.description.abstract | Introduction: The purpose of this study was to use photoelastic analysis to compare the system of forces generated by retraction T-loop springs made with stainless steel and titanium-molybdenum alloy (TMA) (Ormco, Glendora, Calif) with photoelastic analysis. Methods: Three photoelastic models were used to evaluate retraction T-loop springs with the same preactivations in 2 groups. In group 1, the loop was constructed with a stainless steel wire, and 2 helicoids were incorporated on top of the T-loop; in group 2, it was made with TMA and no helicoids. Results: Upon using the qualitative analysis of the fringe order in the photoelastic model, it was observed that the magnitude of force generated by the springs in group 1 was significantly higher than that in group 2. However, both had symmetry for the active and reactive units related to the system of force. Conclusions: Both springs had the same mechanical characteristics. TMA springs showed lower force levels. (Am J Orthod Dentofacial Orthop 2011;140:e123-e128) | en |
dc.description.affiliation | Univ Estadual Paulista, Fac Odontol Araraquara, São Paulo, Brazil | |
dc.description.affiliation | Univ Fed Sergipe, Aracaju, Sergipe, Brazil | |
dc.description.affiliation | St Louis Univ, St Louis, MO 63103 USA | |
dc.description.affiliation | Baylor Coll Dent, Dallas, TX 75246 USA | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Fac Odontol Araraquara, São Paulo, Brazil | |
dc.format.extent | E123-E128 | |
dc.identifier | http://dx.doi.org/10.1016/j.ajodo.2011.03.020 | |
dc.identifier.citation | American Journal of Orthodontics and Dentofacial Orthopedics. New York: Mosby-elsevier, v. 140, n. 3, p. E123-E128, 2011. | |
dc.identifier.doi | 10.1016/j.ajodo.2011.03.020 | |
dc.identifier.issn | 0889-5406 | |
dc.identifier.lattes | 6493049604923160 | |
dc.identifier.uri | http://hdl.handle.net/11449/41886 | |
dc.identifier.wos | WOS:000294678700005 | |
dc.language.iso | eng | |
dc.publisher | Mosby-elsevier | |
dc.relation.ispartof | American Journal of Orthodontics and Dentofacial Orthopedics | |
dc.relation.ispartofjcr | 1.842 | |
dc.relation.ispartofsjr | 1,289 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.title | Photoelastic analysis of forces generated by T-loop springs made with stainless steel or titanium-molybdenum alloy | en |
dc.type | Artigo | |
dcterms.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dcterms.rightsHolder | Mosby-elsevier | |
dspace.entity.type | Publication | |
unesp.author.lattes | 6493049604923160 | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Clínica Infantil - FOAR | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: