Logotipo do repositório
 

Publicação:
Photoelastic analysis of forces generated by T-loop springs made with stainless steel or titanium-molybdenum alloy

dc.contributor.authorMartins Maia, Luiz Guilherme [UNESP]
dc.contributor.authorde Moraes Maia, Mila Leite
dc.contributor.authorMonini, Andre da Costa [UNESP]
dc.contributor.authorVianna, Alexandre Protasio [UNESP]
dc.contributor.authorGandini Júnior, Luiz Gonzaga [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Federal de Sergipe (UFS)
dc.contributor.institutionSt Louis Univ
dc.contributor.institutionBaylor Coll Dent
dc.date.accessioned2014-05-20T15:33:11Z
dc.date.available2014-05-20T15:33:11Z
dc.date.issued2011-09-01
dc.description.abstractIntroduction: The purpose of this study was to use photoelastic analysis to compare the system of forces generated by retraction T-loop springs made with stainless steel and titanium-molybdenum alloy (TMA) (Ormco, Glendora, Calif) with photoelastic analysis. Methods: Three photoelastic models were used to evaluate retraction T-loop springs with the same preactivations in 2 groups. In group 1, the loop was constructed with a stainless steel wire, and 2 helicoids were incorporated on top of the T-loop; in group 2, it was made with TMA and no helicoids. Results: Upon using the qualitative analysis of the fringe order in the photoelastic model, it was observed that the magnitude of force generated by the springs in group 1 was significantly higher than that in group 2. However, both had symmetry for the active and reactive units related to the system of force. Conclusions: Both springs had the same mechanical characteristics. TMA springs showed lower force levels. (Am J Orthod Dentofacial Orthop 2011;140:e123-e128)en
dc.description.affiliationUniv Estadual Paulista, Fac Odontol Araraquara, São Paulo, Brazil
dc.description.affiliationUniv Fed Sergipe, Aracaju, Sergipe, Brazil
dc.description.affiliationSt Louis Univ, St Louis, MO 63103 USA
dc.description.affiliationBaylor Coll Dent, Dallas, TX 75246 USA
dc.description.affiliationUnespUniv Estadual Paulista, Fac Odontol Araraquara, São Paulo, Brazil
dc.format.extentE123-E128
dc.identifierhttp://dx.doi.org/10.1016/j.ajodo.2011.03.020
dc.identifier.citationAmerican Journal of Orthodontics and Dentofacial Orthopedics. New York: Mosby-elsevier, v. 140, n. 3, p. E123-E128, 2011.
dc.identifier.doi10.1016/j.ajodo.2011.03.020
dc.identifier.issn0889-5406
dc.identifier.lattes6493049604923160
dc.identifier.urihttp://hdl.handle.net/11449/41886
dc.identifier.wosWOS:000294678700005
dc.language.isoeng
dc.publisherMosby-elsevier
dc.relation.ispartofAmerican Journal of Orthodontics and Dentofacial Orthopedics
dc.relation.ispartofjcr1.842
dc.relation.ispartofsjr1,289
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.titlePhotoelastic analysis of forces generated by T-loop springs made with stainless steel or titanium-molybdenum alloyen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderMosby-elsevier
dspace.entity.typePublication
unesp.author.lattes6493049604923160
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentClínica Infantil - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: