Logotipo do repositório
 

Publicação:
Simultaneous determination of Cd, Pb, and Cu in atmospheric particulate matter from different regions of the city of Presidente Prudente, Sao Paulo, Brazil

dc.contributor.authorProença, C. A. [UNESP]
dc.contributor.authorBorsato, N. [UNESP]
dc.contributor.authorMaroubo, L. [UNESP]
dc.contributor.authorMoreira-Silva, M. R. [UNESP]
dc.contributor.authorGomes, H. M. [UNESP]
dc.contributor.authorTeixeira, M. F.S. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T16:42:04Z
dc.date.available2018-12-11T16:42:04Z
dc.date.issued2016-07-02
dc.description.abstractThis article explores the assessment of atmospheric deposition, from the analysis of the sampling methods, the analytical procedures for chemical characterisation of pollutants, and the main results from the scientific literature. Atmospheric particulate matter (PM) was collected in four regions of the city of Presidente Prudente (Sao Paulo State, Brazil) characterised by heavy traffic flows and high population density. The Cd, Pb, and Cu metals were determined in samples using differential pulse anodic stripping voltammetry. The PM was collected every fortnight using passive sampling, over a total period of two years. A comparative study between the element deposition fluxes in four sampling sites was performed. The relative contribution of the quantitative descriptors to divergence among the analysis by Tocher grouping method was also studied.en
dc.description.affiliationDepartment of Chemistry and Biochemistry Faculty of Sciences and Technology Sao Paulo University State (UNESP)
dc.description.affiliationUnespDepartment of Chemistry and Biochemistry Faculty of Sciences and Technology Sao Paulo University State (UNESP)
dc.format.extent598-607
dc.identifierhttp://dx.doi.org/10.1080/02757540.2016.1171321
dc.identifier.citationChemistry and Ecology, v. 32, n. 6, p. 598-607, 2016.
dc.identifier.doi10.1080/02757540.2016.1171321
dc.identifier.file2-s2.0-84964009552.pdf
dc.identifier.issn1029-0370
dc.identifier.issn0275-7540
dc.identifier.scopus2-s2.0-84964009552
dc.identifier.urihttp://hdl.handle.net/11449/168590
dc.language.isoeng
dc.relation.ispartofChemistry and Ecology
dc.relation.ispartofsjr0,383
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectatmospheric particulate
dc.subjectMetal deposition flux
dc.subjectTocher method
dc.titleSimultaneous determination of Cd, Pb, and Cu in atmospheric particulate matter from different regions of the city of Presidente Prudente, Sao Paulo, Brazilen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.orcid0000-0001-9355-2143[6]

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-84964009552.pdf
Tamanho:
1.84 MB
Formato:
Adobe Portable Document Format
Descrição:

Coleções