Logotipo do repositório
 

Publicação:
Cyclic and Torsional Fatigue Resistance of Reciprocating Single Files Manufactured by Different Nickel-titanium Alloys

dc.contributor.authorAlcalde, Murilo P.
dc.contributor.authorTanomaru-Filho, Mario [UNESP]
dc.contributor.authorBramante, Clovis M.
dc.contributor.authorDuarte, Marco Antonio H.
dc.contributor.authorGuerreiro-Tanomaru, Juliane Maria [UNESP]
dc.contributor.authorCamilo-Pinto, Jader [UNESP]
dc.contributor.authorReis So, Marcus Vinicius
dc.contributor.authorVivan, Rodrigo Ricci
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniv Fed Rio Grande do Sul
dc.date.accessioned2018-11-26T17:35:08Z
dc.date.available2018-11-26T17:35:08Z
dc.date.issued2017-07-01
dc.description.abstractIntroduction: The aim of this study was to evaluate the cyclic and torsional fatigue resistance of the following reciprocating single-file systems: ProDesign R 25.06 (Easy Equipamentos Odontologicos, Belo Horizonte, Brazil), Reciproc R25 (VDW GmbH, Munich, Germany), and Unicone L25 (Medin SA, Nove Mesto in Morave, Czech Republic). Methods: Sixty instruments of the Pro Design R, Reciproc R25, and Unicone L25 systems (n = 20) were used. Cyclic fatigue resistance was tested measuring the time to failure in an artificial stainless steel canal with a 60 angle and a 5-mm radius of curvature (n = 10). Torque and angle of rotation at failure of new instruments (n = 10) in the 3 mm from the tip portion were measured during torsional testing according to ISO 3630-1. The fractured surface of each fragment was examined by scanning electron microscopy. Data were analyzed using 1-way analysis of variance and Tukey tests, and the level of significance was set at 5%. Results: The cyclic fatigue resistance values of ProDesign.R 25.06 were significantly higher than the other groups (P < .05). Reciproc R25 showed higher fatigue resistance than Unicone L25 (P < .05). In relation to the torsional test, the ProDesign R 25.06 and Unicone L25 systems showed higher angular rotation until fracture than Reciproc R25 (P <.05). However, Reciproc R25 and Unicone L25 showed higher torque load than ProDesign R 25.06 (P <.05). Scanning electron microscopic analysis showed similar and typical features of cyclic and torsional failure for all instruments tested. Conclusions: ProDesign R presented the highest cyclic fatigue resistance and angular rotation to failure compared with Reciproc and Unicone. However, Reciproc showed higher torsional strength to failure.en
dc.description.affiliationUniv Sao Paulo, Bauru Sch Dent, Dept Operat Dent Endodont & Dent Mat, Sao Paulo, Brazil
dc.description.affiliationSao Paulo State Univ, Araraquara Dent Sch, Dept Restorat Dent, Sao Paulo, SP, Brazil
dc.description.affiliationUniv Fed Rio Grande do Sul, Dept Restorat Dent, Porto Alegre, RS, Brazil
dc.description.affiliationUnespSao Paulo State Univ, Araraquara Dent Sch, Dept Restorat Dent, Sao Paulo, SP, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 2014/25520-0
dc.format.extent1186-1191
dc.identifierhttp://dx.doi.org/10.1016/j.joen.2017.03.008
dc.identifier.citationJournal Of Endodontics. New York: Elsevier Science Inc, v. 43, n. 7, p. 1186-1191, 2017.
dc.identifier.doi10.1016/j.joen.2017.03.008
dc.identifier.fileWOS000405164000026.pdf
dc.identifier.issn0099-2399
dc.identifier.urihttp://hdl.handle.net/11449/162974
dc.identifier.wosWOS:000405164000026
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofJournal Of Endodontics
dc.relation.ispartofsjr1,585
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.subjectCyclic fatigue
dc.subjectnickel-titanium
dc.subjectreciprocating systems
dc.subjecttorsional resistance
dc.titleCyclic and Torsional Fatigue Resistance of Reciprocating Single Files Manufactured by Different Nickel-titanium Alloysen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
unesp.author.orcid0000-0002-2574-4706[2]
unesp.author.orcid0000-0003-0446-2037[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt
unesp.departmentOdontologia Restauradora - FOARpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
WOS000405164000026.pdf
Tamanho:
1.03 MB
Formato:
Adobe Portable Document Format
Descrição: