Resumo
A 24-year-old male patient was the victim of a firearm wound that penetrated the thorax. He arrived at another hospital hemodynamically unstable and was submitted to exploratory surgery by means of bithoracotomy. A lesion of the left branch of the pulmonary artery was detected and successfully repaired. He was submitted for computer-aided tomography on the fifth postoperative day, and a lesion of the mid-thoracic aorta was detected, which formed a saccular image. Considering that the patient had already been submitted to a bithoracotomy and that a direct approach to repair would involve another thoracotomy within a short period of time, endovascular treatment was chosen in our hospital. The procedure was performed under fluoroscopy. A second computer-aided tomography indicated adequate treatment of the lesion, with no indication of an endoleak. He has undergone ambulatory follow-up for 36 months without any problem related to the procedure. While endovascular treatment of the aorta has developed enormously, multicenter studies are needed to better define the long-term results of this approach. © 2008 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.
Descrição
Palavras-chave
Aorta , Gunshot wounds , Penetrating wounds , Pseudoaneurysm , adult , aorta disease , artery disease , case report , computer assisted surgery , endoleak , endovascular surgery , false aneurysm , fluoroscopy , follow up , gunshot injury , hemodynamics , hospital discharge , human , lung artery , male , penetrating trauma , postoperative complication , postoperative period , priority journal , surgical technique , thoracic aorta , thoracotomy , Adult , Aneurysm, False , Aortic Aneurysm, Thoracic , Blood Vessel Prosthesis Implantation , Humans , Male , Stents , Surgical Procedures, Minimally Invasive , Tomography, X-Ray Computed , Treatment Outcome , Wounds, Gunshot
Idioma
Inglês
Citação
Interactive Cardiovascular and Thoracic Surgery, v. 7, n. 3, p. 529-530, 2008.