dc.description.abstractIndoor radon concentrations have been measured in Santana cave, the most frequented cave of PETAR (High Ribeira River Tourist State Park), situated southern of São Paulo State, Brazil. The measurements were carried out with CR-39 detectors installed in four of the most frequently visited galleries. Preliminary results from November 2009 to June 2010 show radon concentrations varying from 1.9 +/- 0.1 to 8.4 +/- 0.6 kBq m(-3). The total annual effective dose for all galleries was 3.32 mSv. The complete evaluation will be concluded by September 2010.en
dc.description.affiliationIPEN CNEN SP, Lab Radiometria Ambiental, BR-05508000 São Paulo, Brazil
dc.description.affiliationUniv Estadual Paulista Julio de Meaquita Filho, Inst Geociencias & Ciencias Exatas Rio Claro, BR-13506900 Rio Claro, Brazil
dc.description.affiliationUnespUniv Estadual Paulista Julio de Meaquita Filho, Inst Geociencias & Ciencias Exatas Rio Claro, BR-13506900 Rio Claro, Brazil
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipIdCNPq: 142165/2006-9
dc.format.extent252-255
dc.identifierhttp://dx.doi.org/10.1093/rpd/ncr054
dc.identifier.citationRadiation Protection Dosimetry. Oxford: Oxford Univ Press, v. 145, n. 2-3, p. 252-255, 2011.
dc.identifier.dimensionspub.1060018506
dc.identifier.doi10.1093/rpd/ncr054
dc.identifier.issn0144-8420
dc.identifier.issn1742-3406
dc.identifier.pmid21447503
dc.identifier.urihttp://hdl.handle.net/11449/41998
dc.identifier.wosWOS:000290818900032
dc.language.isoeng
dc.publisherOxford University Press
dc.publisherOxford University Press (OUP)
dc.relation.ispartofRadiation Protection Dosimetry
dc.relation.ispartofjcr0.822
dc.relation.ispartofsjr0,487
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.sourceDimensions
dc.titleAssessment of effective doses from radon levels for tour guides at several galleries of Santana Cave, Southern Brazil, with CR-39 detectors: preliminary resultsen
dc.typeArtigopt
dcterms.licensehttp://www.oxfordjournals.org/access_purchase/self-archiving_policyb.html
dcterms.rightsHolderOxford Univ Press
dspace.entity.typePublication
relation.isOrgUnitOfPublication4763ec56-704e-41e0-9685-b5bef5946feb
relation.isOrgUnitOfPublication.latestForDiscovery4763ec56-704e-41e0-9685-b5bef5946feb
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Geociências e Ciências Exatas, Rio Claropt
unesp.departmentGeografia - IGCEpt

Arquivos