Logo do repositório

Bioabsorbable Polymeric Stent for the Treatment of Coarctation of the Aorta (CoA) in Children: A Methodology to Evaluate the Design and Mechanical Properties of PLA Polymer

dc.contributor.authordos Santos, Flávio José [UNESP]
dc.contributor.authorHernandez, Bruno Agostinho [UNESP]
dc.contributor.authorSantos, Rosana
dc.contributor.authorMachado, Marcel [UNESP]
dc.contributor.authorSouza, Mateus [UNESP]
dc.contributor.authorCapello Sousa, Edson A. [UNESP]
dc.contributor.authorAndrade, Aron
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionDante Pazzanese Institute of Cardiology
dc.date.accessioned2025-04-29T18:35:48Z
dc.date.issued2023-06-01
dc.description.abstractThis study presents a methodology that combines experimental tests and the finite element method, which is able to analyse the influence of the geometry on the mechanical behaviour of stents made of bioabsorbable polymer PLA (PolyLactic Acid) during their expansion in the treatment of coarctation of the aorta (CoA). Tensile tests with standardized specimen samples were conducted to determine the properties of a 3D-printed PLA. A finite element model of a new stent prototype was generated from CAD files. A rigid cylinder simulating the expansion balloon was also created to simulate the stent opening performance. A tensile test with 3D-printed customized stent specimens was performed to validate the FE stent model. Stent performance was evaluated in terms of elastic return, recoil, and stress levels. The 3D-printed PLA presented an elastic modulus of 1.5 GPa and a yield strength of 30.6 MPa, lower than non-3D-printed PLA. It can also be inferred that crimping had little effect on stent circular recoil performance, as the difference between the two scenarios was on average 1.81%. For an expansion of diameters ranging from 12 mm to 15 mm, as the maximum opening diameter increases, the recoil levels decrease, ranging from 10 to 16.75% within the reported range. These results point out the importance of testing the 3D-printed PLA under the conditions of using it to access its material properties; the results also indicate that the crimping process could be disregarded in simulations to obtain fast results with lower computational cost and that new proposed stent geometry made of PLA might be suitable for use in CoA treatments—the approach that has not been applied before. The next steps will be to simulate the opening of an aorta vessel using this geometry.en
dc.description.affiliationDepartment of Mechanical Engineering Centre for Simulation in Bioengineering Biomechanics and Biomaterials School of Engineering (CS3B) UNESP São Paulo State University, Campus of Bauru
dc.description.affiliationDepartment of Engineering PUC—Pontifical Catholic University of São Paulo
dc.description.affiliationCEAC—Centre for Engineering in Circulatory Assistance Dante Pazzanese Institute of Cardiology
dc.description.affiliationUnespDepartment of Mechanical Engineering Centre for Simulation in Bioengineering Biomechanics and Biomaterials School of Engineering (CS3B) UNESP São Paulo State University, Campus of Bauru
dc.identifierhttp://dx.doi.org/10.3390/ma16124403
dc.identifier.citationMaterials, v. 16, n. 12, 2023.
dc.identifier.doi10.3390/ma16124403
dc.identifier.issn1996-1944
dc.identifier.scopus2-s2.0-85163810983
dc.identifier.urihttps://hdl.handle.net/11449/297971
dc.language.isoeng
dc.relation.ispartofMaterials
dc.sourceScopus
dc.subjectbioabsorbable stent
dc.subjectcoarctation of the aorta
dc.subjectfinite element analysis
dc.titleBioabsorbable Polymeric Stent for the Treatment of Coarctation of the Aorta (CoA) in Children: A Methodology to Evaluate the Design and Mechanical Properties of PLA Polymeren
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublication47f5cbd3-e1a4-4967-9c9f-2747e6720d28
relation.isOrgUnitOfPublication.latestForDiscovery47f5cbd3-e1a4-4967-9c9f-2747e6720d28
unesp.author.orcid0000-0001-7425-3690[1]
unesp.author.orcid0000-0002-2716-4262[2]
unesp.author.orcid0000-0002-0540-7956[3]
unesp.author.orcid0000-0002-4452-9497[4]
unesp.author.orcid0000-0003-4749-6659[5]
unesp.author.orcid0000-0003-0613-1151[6]
unesp.author.orcid0000-0002-4859-5897[7]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Baurupt

Arquivos