Publicação: Resposta biológica frente a diferentes fios de sutura : estudo comparativo em ratos
dc.contributor.advisor | Souza, Francisley Ávila [UNESP] | |
dc.contributor.author | Mendes, Kezia Barbosa [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2023-07-14T17:13:50Z | |
dc.date.available | 2023-07-14T17:13:50Z | |
dc.date.issued | 2023-06-28 | |
dc.description.abstract | Atualmente existe uma grande variedade de fios de sutura, com propriedades físicas, mecânicas e químicas distintas entre si, no intuito de diferentes indicações de emprego. O objetivo deste estudo foi avaliar microscopicamente a reação inflamatória de diferentes materiais de síntese suturados em plano muscular e derme de ratos. Foram utilizados 4 tipos de fios: Seda 4-0, Nylon 4-0, Polipropileno 4-0 (Techsuture Ind e Com de Produtos Cirúrgicos Ltda, Bauru, Brasil) e Poliglactina 910 (Vicryl 4-0, Ethicon, Jhonson, São José dos Campos, Brasil). 18 ratos Novergicus albinus wistar foram submetidos à procedimento cirúrgico através de incisão dorsal única, acessando o plano muscular por divulsão e realizado a sutura em 4 áreas, utilizando um ponto simples para cada fio. Todos os animais receberam os 4 tipos de fios e foram separados em grupos de 6 animais de acordo com os tempos de eutanásia: 5, 10 e 20 dias. O material coletado foi fixado em formaldeído 10%, seguido de processamento laboratorial para inclusão em parafina e realização de cortes histológicos de 5um. As lâminas coradas com HE foram analisadas em microscópio óptico acoplado a uma câmera. Os resultados mostraram reação inflamatória intensa ao redor do fio de seda nos períodos iniciais (5 e 10 dias) em derme e músculo, moderada aos 5 dias no fio de poligalactina 910, decrescente no período de 10 dias e ausente aos 20 dias; ausência de inflamação polipropileno e inflamação moderada em nylon em derme aos 5 e 10 dias. Com isso, foi possível concluir que as reações inflamatórias diferiram em todos os fios estudados, sendo mais intensa ao fio de seda; o fio de poliglactina 910 apresentou reação inflamatória decrescente; foi observado alta biocompatibilidade nos fios de nylon e polipropileno. | pt |
dc.description.abstract | Currently, there is a wide variety of suture threads, with different physical, mechanical and chemical properties among them for different indications of employment. The purpose of this study was to microscopically evaluate the inflammatory reaction of different synthesis materials sutured in the muscular and dermis plane of rats. Four types of threads were used: Silk 4-0, Nylon 4-0, Polypropylene 4-0 (Techsuture Ind e Com de Produtos Cirúrgicos Ltda, Bauru, Brazil) and Polygalactina 910 (Vicryl 4-0, Ethicon, Jhonson, São José dos Campos, Brazil). 18 Novergicus albinus wistar rats were submitted to the surgical procedure through a single dorsal incision, accessing the muscular plane by divulsion and suturing was performed in 4 areas, using a single stitch for each thread. All animals received the 4 types of wires and were separated into groups of 6 animals according to the times of euthanasia: 5, 10 and 20 days. The collected material was fixed in 10% formaldehyde, followed by laboratory processing for embedding in paraffin and performing 5um histological sections. The slides stained with HE were analyzed in an optical microscope coupled to a camera. The results showed an intense inflammatory reaction around the silk thread at the first 5 and 10 days, moderate at 5 days in the polygalactin 910 thread, decreasing after 10 days and absent at 20 days; no polypropylene inflammation and moderate nylon inflammation in dermis at the 5 and 10 days. With this, it was possible to conclude that the inflammatory reactions differed in all the threads studied, being more intense in the silk thread; the polygalactin 910 thread showed a decreasing inflammatory reaction; high biocompatibility was observed in nylon and polypropylene threads. | pt |
dc.identifier.uri | http://hdl.handle.net/11449/244592 | |
dc.language.iso | por | |
dc.publisher | Universidade Estadual Paulista (Unesp) | |
dc.rights.accessRights | Acesso aberto | pt |
dc.subject | Inflamação | pt |
dc.subject | Suturas | pt |
dc.subject | Ratos | pt |
dc.subject | Inflammation | en |
dc.title | Resposta biológica frente a diferentes fios de sutura : estudo comparativo em ratos | pt |
dc.title.alternative | Biological response to different suture threads: comparative study in rats | en |
dc.type | Trabalho de conclusão de curso | pt |
dspace.entity.type | Publication | |
relation.isOrgUnitOfPublication | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
relation.isOrgUnitOfPublication.latestForDiscovery | 8b3335a4-1163-438a-a0e2-921a46e0380d | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatuba | pt |
unesp.undergraduate | Odontologia - FOA | pt |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- mendes_kb_tcc_foa.pdf
- Tamanho:
- 1.06 MB
- Formato:
- Adobe Portable Document Format
- Descrição:
Licença do Pacote
1 - 2 de 2
Carregando...
- Nome:
- license.txt
- Tamanho:
- 2.43 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Carregando...
- Nome:
- mendes_kb_autorizacao_foa.pdf
- Tamanho:
- 955.44 KB
- Formato:
- Adobe Portable Document Format
- Descrição: