Publicação: Influence of Frequency-Dependent Soil Models with Variable Water Content on Transient Responses of Overhead Transmission Lines
dc.contributor.author | Pascoalato, Taina Fernanda Garbelim [UNESP] | |
dc.contributor.author | De Araujo, Anderson Ricardo Justo | |
dc.contributor.author | Kurokawa, Sergio [UNESP] | |
dc.contributor.author | Filho, Jose Pissolato | |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | |
dc.contributor.institution | Universidade Estadual de Campinas (UNICAMP) | |
dc.date.accessioned | 2023-07-29T15:13:43Z | |
dc.date.available | 2023-07-29T15:13:43Z | |
dc.date.issued | 2022-01-01 | |
dc.description.abstract | This paper provides a short review and a comparison of three soil models, Scott (S), Longmire-Smith (LS) and Messier (M), where the effect of variation of water content on its frequency-dependent electrical parameters are considered. The transient performance of voltages developed for a lightning strike on a three-phase overhead transmission line (TL) above this type of soil are computed. The current is injected at the phase 1 and the voltages at receiving ends of phase 1, 2 and 3 are analyzed. Results demonstrated that the LS model result into the lowest values of the resistivity and relative permittivity for the same range of frequency and water content. As a consequence, the voltages at the phase 1 have no impact for these soil models whereas the induced voltages are strongly affected where the LS model provided an expressive reduction at the peaks. | en |
dc.description.affiliation | São Paulo State University (UNESP) Department of Electrical Engineering | |
dc.description.affiliation | School of Electrical and Computing Engineering State University of Campinas (UNICAMP) | |
dc.description.affiliationUnesp | São Paulo State University (UNESP) Department of Electrical Engineering | |
dc.identifier | http://dx.doi.org/10.1109/PESGM48719.2022.9917182 | |
dc.identifier.citation | IEEE Power and Energy Society General Meeting, v. 2022-July. | |
dc.identifier.doi | 10.1109/PESGM48719.2022.9917182 | |
dc.identifier.issn | 1944-9933 | |
dc.identifier.issn | 1944-9925 | |
dc.identifier.scopus | 2-s2.0-85141524472 | |
dc.identifier.uri | http://hdl.handle.net/11449/249350 | |
dc.language.iso | eng | |
dc.relation.ispartof | IEEE Power and Energy Society General Meeting | |
dc.source | Scopus | |
dc.subject | Electromagnetic transients | |
dc.subject | frequency-dependent soil | |
dc.subject | lightning performance | |
dc.subject | water content | |
dc.title | Influence of Frequency-Dependent Soil Models with Variable Water Content on Transient Responses of Overhead Transmission Lines | en |
dc.type | Trabalho apresentado em evento | |
dspace.entity.type | Publication | |
unesp.department | Engenharia Elétrica - FEIS | pt |