Publicação: Simplified skin-effect formulation for power transmission lines
dc.contributor.author | Monteiro, Jose Humberto A. [UNESP] | |
dc.contributor.author | Costa, Eduardo Coelho M. | |
dc.contributor.author | Pinto, Andre Jinno G. [UNESP] | |
dc.contributor.author | Kurokawa, Sergio | |
dc.contributor.author | Gatous, Omar Mohamed O. | |
dc.contributor.author | Pissolato, Jose | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade Estadual de Campinas (UNICAMP) | |
dc.contributor.institution | Higher Inst Med Technol | |
dc.date.accessioned | 2014-12-03T13:09:00Z | |
dc.date.available | 2014-12-03T13:09:00Z | |
dc.date.issued | 2014-03-01 | |
dc.description.abstract | This study presents a simplified formulation to calculate the skin effect on transmission lines wires. The methodology is developed from the solution of the time-domain Maxwell's wave equations whose frequency-domain solutions are obtained using Fourier transforms. Results obtained from the proposed formulation are compared with those calculated using the conventional method based on the approach by Bessel functions. The proposed skin-effect formulation is also validated based on electromagnetic transients simulations in the time domain considering a conventional 69-kV transmission system. | en |
dc.description.affiliation | Univ Estadual Paulista, Fac Engn Ilha Solteira, Ilha Solteira, SP, Brazil | |
dc.description.affiliation | Univ Estadual Campinas, Fac Engn Eletr Comp, Campinas, SP, Brazil | |
dc.description.affiliation | Higher Inst Med Technol, Misrata, Libya | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Fac Engn Ilha Solteira, Ilha Solteira, SP, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | |
dc.description.sponsorshipId | FAPESP: 13/00974-5 | |
dc.description.sponsorshipId | CAPES: Procs. PDSE 4570/11-1 | |
dc.description.sponsorshipId | CAPES: PDSE 6851/12-6 | |
dc.format.extent | 47-53 | |
dc.identifier | http://dx.doi.org/10.1049/iet-smt.2013.0072 | |
dc.identifier.citation | Iet Science Measurement & Technology. Hertford: Inst Engineering Technology-iet, v. 8, n. 2, p. 47-53, 2014. | |
dc.identifier.doi | 10.1049/iet-smt.2013.0072 | |
dc.identifier.issn | 1751-8822 | |
dc.identifier.lattes | 4830845230549223 | |
dc.identifier.uri | http://hdl.handle.net/11449/111814 | |
dc.identifier.wos | WOS:000331699200001 | |
dc.language.iso | eng | |
dc.publisher | Inst Engineering Technology-iet | |
dc.relation.ispartof | Iet Science Measurement & Technology | |
dc.relation.ispartofjcr | 1.336 | |
dc.relation.ispartofsjr | 0,352 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.title | Simplified skin-effect formulation for power transmission lines | en |
dc.type | Artigo | |
dcterms.rightsHolder | Inst Engineering Technology-iet | |
dspace.entity.type | Publication | |
unesp.author.lattes | 4830845230549223 | |
unesp.author.orcid | 0000-0002-9263-980X[4] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Engenharia, Ilha Solteira | pt |
unesp.department | Engenharia Elétrica - FEIS | pt |