Surface and intra-pulpal temperature variation during tooth whitening photoactivated with LED/laser
| dc.contributor.author | Costa, Joatan Lucas de Sousa Gomes | |
| dc.contributor.author | Gelio, Mariana Bena [UNESP] | |
| dc.contributor.author | Galvani, Lucas David [UNESP] | |
| dc.contributor.author | Besegato, João Felipe | |
| dc.contributor.author | Bordini, Ester Alves Ferreira | |
| dc.contributor.author | Godoy, Eduardo Fernández | |
| dc.contributor.author | Vaz, Luis Geraldo [UNESP] | |
| dc.contributor.author | Kuga, Milton Carlos | |
| dc.contributor.institution | Universidade Federal de Minas Gerais (UFMG) | |
| dc.contributor.institution | Universidade Estadual Paulista (UNESP) | |
| dc.contributor.institution | Universidade Federal de Mato Grosso do Sul (UFMS) | |
| dc.contributor.institution | Universidade de São Paulo (USP) | |
| dc.contributor.institution | Universidad Autónoma de Chile | |
| dc.date.accessioned | 2025-04-29T20:02:28Z | |
| dc.date.issued | 2023-01-01 | |
| dc.description.abstract | This study evaluated the variation of surface and intra-pulpal temperature, during bleaching protocol, using LED/laser. The 35% (HP35), 15% (HP15) and 6% (HP6) gels were used associated with LED/laser applied every 1 min for 30 min in a human canine. The evaluation of surface temperature variation (∆Ts) was performed using a pHmeter and the intra-pulpal temperature variation (∆Ti) was performed using a digital thermometer, at times of 1-, 5-, 10-15-and 30-min. Statistical analysis was performed using the two-way repeated measures ANOVA test and Bonferroni post-hoc test was used at a significance level of 5%. HP35 and HP15 showed greater temperature variation than HP6 up to 10 min of surface evaluation, showing no differences between them. In the intra-pulpal evaluation, no group showed differences throughout the procedure. | en |
| dc.description.affiliation | Department of Restorative Dentistry School of Dentistry Federal University of Minas Gerais —UFMG, MG | |
| dc.description.affiliation | Department of Restorative Dentistry School of Dentistry São Paulo State University —UNESP, SP | |
| dc.description.affiliation | School of Dentistry Federal University of Mato Grosso do Sul —UFMS, MS | |
| dc.description.affiliation | Department of Operative Dentistry Endodontics and Dental Materials Bauru School of Dentistry University of São Paulo —USP, SP | |
| dc.description.affiliation | Instituto de Ciencias Biomédicas Universidad Autónoma de Chile | |
| dc.description.affiliation | Department of Dental Materials and Prosthodontics School of Dentistry São Paulo State University —UNESP, SP | |
| dc.description.affiliationUnesp | Department of Restorative Dentistry School of Dentistry São Paulo State University —UNESP, SP | |
| dc.description.affiliationUnesp | Department of Dental Materials and Prosthodontics School of Dentistry São Paulo State University —UNESP, SP | |
| dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | |
| dc.description.sponsorshipId | CAPES: 001 | |
| dc.format.extent | 654-658 | |
| dc.identifier | http://dx.doi.org/10.4012/dmj.2023-017 | |
| dc.identifier.citation | Dental Materials Journal, v. 42, n. 5, p. 654-658, 2023. | |
| dc.identifier.doi | 10.4012/dmj.2023-017 | |
| dc.identifier.issn | 1881-1361 | |
| dc.identifier.issn | 0287-4547 | |
| dc.identifier.scopus | 2-s2.0-85173515376 | |
| dc.identifier.uri | https://hdl.handle.net/11449/305220 | |
| dc.language.iso | eng | |
| dc.relation.ispartof | Dental Materials Journal | |
| dc.source | Scopus | |
| dc.subject | Dental bleaching | |
| dc.subject | Hydrogen peroxide | |
| dc.subject | Temperature | |
| dc.subject | Violet LED | |
| dc.title | Surface and intra-pulpal temperature variation during tooth whitening photoactivated with LED/laser | en |
| dc.type | Artigo | pt |
| dspace.entity.type | Publication |

