Logotipo do repositório

Digital Smile Design and mock-up technique in esthetic crown lengthening: 2-year follow-up of six cases

dc.contributor.authorPires, Luana Carla
dc.contributor.authorLeandrin, Thais Piragine [UNESP]
dc.contributor.authorAroni, Mauricio Andres Tinajero
dc.contributor.authorde Oliveira, Guilherme José Pimentel Lopes
dc.contributor.authorBarbeiro, Roberto Henrique [UNESP]
dc.contributor.authorVerzola, Mario Henrique
dc.contributor.authorCirelli, Joni Augusto [UNESP]
dc.contributor.authorPigossi, Suzane Cristina
dc.contributor.institutionSchool of Dentistry
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionSan Francisco de Quito University (USFQ)
dc.contributor.institutionUberlandia Federal University (UFU)
dc.contributor.institutionAlfenas Federal University (Unifal-MG)
dc.date.accessioned2025-04-29T19:28:37Z
dc.date.issued2022-03-01
dc.description.abstractThe present case series aimed to evaluate the use of a Digital Smile Design (DSD) and mock-up technique for esthetic crown lengthening (ECL) surgery in six clinical cases with a 2-year follow-up. Six nonsmoker patients (five females, one male; aged 22 to 32 years), periodontally and systemically healthy, with inadequate tooth width/height ratio proportions associated with a gingival misalignment in the anterior maxilla were included. The DSDs were created using PowerPoint for all patients to evaluate gingival level and tooth form/contour. A wax-up and mock-up were created based on the DSD measurements. ECL surgeries were performed in all cases using the mock-up technique to determine the final gingival margin position and the amount of bone resection needed. A mock-up to bone crest distance of 3 mm was obtained in all cases. Using patient photographs, comparisons were made between the dental crown length (DCL) measurements obtained before the surgical procedure (baseline; T0), on the DSD template immediately postoperatively (IPO; T1), and at the 2-year follow-up (T2). A DCL augmentation of 1.16 ± 0.68 mm was obtained at T1, with an augmentation of 1.03 ± 0.73 mm at T2. Moreover, a minimal difference of 0.34 ± 0.74 mm between the DCL planned in the DSD template and the DCL obtained IPO was observed. In conclusion, the ECL procedure based on the DSD concept and mock-up technique proposed in this cases series was a predictable protocol for smile disharmony treatment in all the patients.en
dc.description.affiliationCentro Universitário Central Paulista UNICEP School of Dentistry
dc.description.affiliationDepartment of Restorative Dentistry School of Dentistry at Araraquara UNESP São Paulo State University
dc.description.affiliationDepartment of Periodontics and Implant Dentistry San Francisco de Quito University (USFQ)
dc.description.affiliationDepartment of Periodontology School of Dentistry Uberlandia Federal University (UFU), Minas Gerais
dc.description.affiliationDepartment of Diagnosis and Surgery School of Dentistry at Araraquara UNESP São Paulo State University
dc.description.affiliationDepartment of Clinics and Surgery School of Dentistry Alfenas Federal University (Unifal-MG), Minas Gerais
dc.description.affiliationUnespDepartment of Restorative Dentistry School of Dentistry at Araraquara UNESP São Paulo State University
dc.description.affiliationUnespDepartment of Diagnosis and Surgery School of Dentistry at Araraquara UNESP São Paulo State University
dc.format.extent58-75
dc.identifier.citationInternational Journal of Esthetic Dentistry, v. 17, n. 1, p. 58-75, 2022.
dc.identifier.issn2198-591X
dc.identifier.scopus2-s2.0-85124775783
dc.identifier.urihttps://hdl.handle.net/11449/303108
dc.language.isoeng
dc.relation.ispartofInternational Journal of Esthetic Dentistry
dc.sourceScopus
dc.titleDigital Smile Design and mock-up technique in esthetic crown lengthening: 2-year follow-up of six casesen
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublicationca4c0298-cd82-48ee-a9c8-c97704bac2b0
relation.isOrgUnitOfPublication.latestForDiscoveryca4c0298-cd82-48ee-a9c8-c97704bac2b0
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquarapt

Arquivos