Logo do repositório
 

Effect of Vertical Misfit on Screw Joint Stability of Implant-Supported Crowns

dc.contributor.authorAssunção, Wirley Goncalves [UNESP]
dc.contributor.authorDelben, Juliana Aparecida [UNESP]
dc.contributor.authorTabata, Lucas Fernando [UNESP]
dc.contributor.authorRicardo Barao, Valentim Adelino [UNESP]
dc.contributor.authorGomes, Erica Alves [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:30:25Z
dc.date.accessioned2014-05-20T13:43:54Z
dc.date.available2013-09-30T18:30:25Z
dc.date.available2014-05-20T13:43:54Z
dc.date.issued2011-08-01
dc.description.abstractThe passive fit between prosthesis and implant is a relevant factor for screw joint stability and treatment success. The aim of this study was to evaluate the influence of vertical misfit in abutment-implant interface on preload maintenance of retention screw of implant-supported crowns. The crowns were fabricated with different abutments and veneering materials and divided into 5 groups (n = 12): Gold UCLA abutments cast in gold alloy veneered with ceramic (Group I) and resin (Group II), UCLA abutments cast in titanium veneered with ceramic (Group III) and resin (Group IV), and zirconia abutments with ceramic veneering (Group V). The crowns were attached to implants by gold retention screws with 35-N cm insertion torque. Specimens were submitted to mechanical cycling up to 10(6) cycles. Measurements of detorque and vertical misfit in abutment-implant interface were performed before and after mechanical cycling. ANOVA revealed statistically significant difference (P < 0.05) among groups for vertical misfit measured before and after mechanical cycling. The abutments cast in titanium exhibited the highest misfit values. Pearson correlation test did not demonstrate significant correlation (P > 0.05) between vertical misfit and detorque value. It was concluded that vertical misfit did not influence torque maintenance and the abutments cast in titanium exhibited the highest misfit values.en
dc.description.affiliationSão Paulo State Univ UNESP, Dept Dent Mat & Prosthodont, Aracatuba Dent Sch, São Paulo, Brazil
dc.description.affiliationUniv Estadual Paulista, Dept Dent Mat & Prosthodont, Fac Odontol Aracatuba, BR-16015050 São Paulo, Brazil
dc.description.affiliationUnespSão Paulo State Univ UNESP, Dept Dent Mat & Prosthodont, Aracatuba Dent Sch, São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Dept Dent Mat & Prosthodont, Fac Odontol Aracatuba, BR-16015050 São Paulo, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 07/53140-3
dc.description.sponsorshipIdFAPESP: 07/04181-9
dc.format.extent947-951
dc.identifierhttp://dx.doi.org/10.1007/s11665-010-9699-9
dc.identifier.citationJournal of Materials Engineering and Performance. New York: Springer, v. 20, n. 6, p. 947-951, 2011.
dc.identifier.doi10.1007/s11665-010-9699-9
dc.identifier.fileWOS000292749800012.pdf
dc.identifier.issn1059-9495
dc.identifier.lattes4438747643373395
dc.identifier.urihttp://hdl.handle.net/11449/15359
dc.identifier.wosWOS:000292749800012
dc.language.isoeng
dc.publisherSpringer
dc.relation.ispartofJournal of Materials Engineering and Performance
dc.relation.ispartofjcr1.340
dc.relation.ispartofsjr0,611
dc.rights.accessRightsAcesso abertopt
dc.sourceWeb of Science
dc.subjectcastingen
dc.subjectmaterial selectionen
dc.subjectopticalmicroscopyen
dc.subjecttitaniumen
dc.titleEffect of Vertical Misfit on Screw Joint Stability of Implant-Supported Crownsen
dc.typeArtigopt
dcterms.licensehttp://www.asminternational.org/pdf/JTST_copyright.pdf
dcterms.rightsHolderSpringer
dspace.entity.typePublication
relation.isDepartmentOfPublication5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isDepartmentOfPublication.latestForDiscovery5f53b343-da2a-4737-96ec-6e2389a6d704
relation.isOrgUnitOfPublication8b3335a4-1163-438a-a0e2-921a46e0380d
relation.isOrgUnitOfPublication.latestForDiscovery8b3335a4-1163-438a-a0e2-921a46e0380d
unesp.author.lattes4438747643373395
unesp.author.orcid0000-0002-8903-0737[1]
unesp.author.orcid0000-0002-6391-9917[4]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araçatubapt
unesp.departmentMateriais odontológicos e Prótese - FOApt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
WOS000292749800012.pdf
Tamanho:
287.64 KB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: