Publicação: Comparison of the Stability of Mandibular Sagittal Osteotomy Fixation between Two Types of Titanium Miniplates: A Biomechanical Study in Sheep Mandibles
Nenhuma Miniatura disponível
Data
2018-06-01
Orientador
Coorientador
Pós-graduação
Curso de graduação
Título da Revista
ISSN da Revista
Título de Volume
Editor
Thieme Medical Publ Inc
Tipo
Artigo
Direito de acesso
Acesso restrito
Resumo
This study aimed to compare the biomechanical stability of the fixation of mandibular sagittal split osteotomy of the ramus by two types of titanium miniplates in sheep mandibles. Seven preserved sheep mandibles with similar weight and size were selected, dissected with complete removal of soft-tissue structures, and sectioned in their midline. After performing sagittal split osteotomy, 5mm of advancement was standardized and samples were divided into two groups according to the type of titanium miniplate (GI = seven hemimandibles were fixed with straight titanium miniplate, GII = seven hemimandibles were fixed with L-shaped titanium miniplates), and then subjected to compressive load. The means (standard deviation) of the compressive load and extension values were 70.68 N (22.26) and 63.36 mm (15.60) to straight miniplates, and 78.80 N (32.54) and 70.55 mm (5.42) to L-shaped miniplates. After comparison and statistical analysis, the results showed no significant difference between the two types of titanium miniplates.