Publicação: Implants with hydrophilic surfaces equalize the osseointegration of implants in normo- and hyperglycaemic rats
dc.contributor.author | Pinotti, Felipe Eduardo [UNESP] | |
dc.contributor.author | Aron, Mauricio Andrés Tinajero | |
dc.contributor.author | Lopes de Oliveira, Guilherme José Pimentel | |
dc.contributor.author | Marcantonio, Elcio [UNESP] | |
dc.contributor.author | Chiérici Marcantonio, Rosemarv Adriana [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | |
dc.contributor.institution | Universidade Federal de Sergipe (UFS) | |
dc.contributor.institution | Universidade Federal de Uberlândia (UFU) | |
dc.date.accessioned | 2023-07-29T15:41:42Z | |
dc.date.available | 2023-07-29T15:41:42Z | |
dc.date.issued | 2022-01-01 | |
dc.description.abstract | The purpose of this study was to evaluate the effect of a surface modified by blasting and acid attack and maintained in an isotonic solution compared to a machined surface on osseointegration in normo- and hyperglycaemic animals. Sixty-four animals were allocated into 4 groups with 16 animals each, and they were subdivided into two experimental periods (15 and 45 days), with 8 animals in each group. The groups were divided according to the type of implant that was installed in the animals' tibia and the animals' systemic condition: CM - Machined implants placed in Healthy animals; CH - Hydrophilic implants placed in Healthy animals, HM - Machined implants placed in animals with hyperglycaemia; HH- Hydrophilic implants installed in animals with hyperglycaemia. The following analyses were performed: biomechanical (removal torque), microtomographic (evaluation of the bone volume around the implants- BV/TV), and histomorphometric (evaluation of bone-implant contact BIC% and of the bone formation area between the threads BBT%). It was found that the implants with hydrophilic surfaces presented higher removal torques and quantities of BV/TV% and higher BIC% and BBT% values in normo- and hyperglycaemic animals. The results of this study indicated that the hydrophilic surface accelerates the osseointegration process (~ 15% BIC/BBT at 15-day period), especially in animals with hyperglycaemia. The hydrophilic surface equaled the osseointegration between normo- and hyperglycaemic animals, reversing the negative potential of hyperglycaemia on the osseointegration process. | en |
dc.description.affiliation | Department of Diagnosis and Surgery São Paulo State University (Unesp) School of Dentistry | |
dc.description.affiliation | Department of Periodontology San Francisco de Quito University (UFSQ) | |
dc.description.affiliation | Department of Periodontology and Implantology School of Dentistry Universidade Federal de Uberlândia | |
dc.description.affiliationUnesp | Department of Diagnosis and Surgery São Paulo State University (Unesp) School of Dentistry | |
dc.format.extent | 71-77 | |
dc.identifier | http://dx.doi.org/10.1590/0103-6440202204793 | |
dc.identifier.citation | Brazilian Dental Journal, v. 33, n. 6, p. 71-77, 2022. | |
dc.identifier.doi | 10.1590/0103-6440202204793 | |
dc.identifier.issn | 1806-4760 | |
dc.identifier.issn | 0103-6440 | |
dc.identifier.scopus | 2-s2.0-85143553861 | |
dc.identifier.uri | http://hdl.handle.net/11449/249452 | |
dc.language.iso | eng | |
dc.relation.ispartof | Brazilian Dental Journal | |
dc.source | Scopus | |
dc.subject | diabetes | |
dc.subject | implant surface | |
dc.subject | osseointegration | |
dc.title | Implants with hydrophilic surfaces equalize the osseointegration of implants in normo- and hyperglycaemic rats | en |
dc.type | Artigo | |
dspace.entity.type | Publication | |
unesp.author.orcid | 0000-0002-1555-6242[1] | |
unesp.author.orcid | 0000-0002-4291-5589[2] | |
unesp.author.orcid | 0000-0001-8778-0115[3] | |
unesp.author.orcid | 0000-0003-1294-2305[4] | |
unesp.author.orcid | 0000-0002-5052-7439[5] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Diagnóstico e Cirurgia - FOAR | pt |