Publicação: Use of bispectral index to monitor depth of anesthesia in isoflurane-anesthetized dogs
dc.contributor.author | Campagnol, Daniela | |
dc.contributor.author | Teixeira Neto, Francisco José [UNESP] | |
dc.contributor.author | Monteiro, Eduardo R. | |
dc.contributor.author | Beier, Suzane L. | |
dc.contributor.author | Aguiar, Antonio J. A. | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T13:31:53Z | |
dc.date.available | 2014-05-20T13:31:53Z | |
dc.date.issued | 2007-12-01 | |
dc.description.abstract | Objective-To evaluate the correlation between the bispectral index (BIS) and end-tidal isoflurane (ETISO) concentration and compare the use of 3 BIS sensor positions in dogs.Animals-6 adult dogs.Procedures-Mechanically ventilated dogs received pancuronium, and depth of anesthesia was altered by increasing ETISO concentration from 1.5% to 2.3% and 3.0%. The BIS, suppression ratio (relative percentage of isoelectric electroencephalographic waveforms), and signal quality index (SQI) were recorded at each ET, so concentration for each of 3 BIS sensor positions (frontal-occipital, bifrontal, and frontal-temporal positions).Results-The BIS and ETISO concentration were poorly correlated-, regardless of sensor positioning, mean BIS values did not change significantly as ETISO was increased. At 3% isoflurane, regardless of sensor positioning, there was an increase in suppression ratio coincident with BIS < 40 in some dogs, whereas paradoxic increases in BIS (> 60) were recorded in others. Furthermore, at 3.0% isoflurane, the SQI was significantly lower for the bifrontal sensor position (compared with values for the other positions), but low SQI values prevented recording of BIS values from the frontal-occipital sensor position in 2 dogs. Overall, BIS values derived from the 3 sensor positions did not differ.Conclusions and Clinical Relevance-In dogs, BIS values may not reflect changes in depth of isoflurane anesthesia in the absence of noxious stimulation. of the 3 sensor positions, frontal-temporal positioning provided better correlation with changes in depth of anesthesia induced via changes in isoflurane concentrations. However, the sensor placements yielded similar results at SQI values > 50. | en |
dc.description.affiliation | Univ Estadual Paulista, Fac Med Vet, Dept Vet Surg & Anesthesiol, Botucatu, SP, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Fac Med Vet, Dept Vet Surg & Anesthesiol, Botucatu, SP, Brazil | |
dc.format.extent | 1300-1307 | |
dc.identifier | http://dx.doi.org/10.2460/ajvr.68.12.1300 | |
dc.identifier.citation | American Journal of Veterinary Research. Schaumburg: Amer Veterinary Medical Assoc, v. 68, n. 12, p. 1300-1307, 2007. | |
dc.identifier.doi | 10.2460/ajvr.68.12.1300 | |
dc.identifier.issn | 0002-9645 | |
dc.identifier.uri | http://hdl.handle.net/11449/10862 | |
dc.identifier.wos | WOS:000251355200004 | |
dc.language.iso | eng | |
dc.publisher | Amer Veterinary Medical Assoc | |
dc.relation.ispartof | American Journal of Veterinary Research | |
dc.relation.ispartofjcr | 0.833 | |
dc.relation.ispartofsjr | 0,567 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.title | Use of bispectral index to monitor depth of anesthesia in isoflurane-anesthetized dogs | en |
dc.type | Artigo | |
dcterms.license | https://www.avma.org/News/Journals/Pages/journals-reprints.aspx | |
dcterms.rightsHolder | Amer Veterinary Medical Assoc | |
dspace.entity.type | Publication | |
unesp.author.lattes | 7162819131462797[5] | |
unesp.author.orcid | 0000-0001-6854-722X[5] | |
unesp.author.orcid | 0000-0002-3002-8093[2] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Medicina Veterinária e Zootecnia, Botucatu | pt |
unesp.department | Cirurgia e Anestesiologia Veterinária - FMVZ | pt |
Arquivos
Licença do Pacote
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: