Avaliação (em escala laboratorial) da aplicação do processo eletrolítico em efluente de lagoa de estabilização de esgoto urbano
Alternative title
(Laboratory scale) assessment of electrolytic processing of effluent from a urban sewage stabilization lagoonAuthor
Date
2010-01-01Type
Article

View/ Open
Access rights
Open access 

Metadata
Show full item recordAbstract
Physico-chemical and microbiological parameters were evaluated before and after applying an electrolytic process to effluents of a stabilization lagoon, in the presence or absence of salt. Chlorine generation and bactericidal properties of the treatments were studied following two experiments. Effluent pH increased with electrolysis time. In the absence of salt, 20 min electrolysis resulted in a COD (Chemical Oxygen Demand) reduction of 44%, along with ca. 99.9% (3 log10 cfu/mL) reduction in total coliforms, heterotrophic bacteria and Escherichia coli. These results indicated that the electrolytic process is a promising complementary technology to improve effluent quality for stabilization lagoons.
How to cite this document
Claro, Elis Marina Turini et al. Avaliação (em escala laboratorial) da aplicação do processo eletrolítico em efluente de lagoa de estabilização de esgoto urbano. Química Nova. Sociedade Brasileira de Química, v. 33, n. 3, p. 557-561, 2010. Available at: <http://hdl.handle.net/11449/20095>.
Language
Portuguese