Adjustment of the hazen-willians equation for determination of continuous pressure drop in PVC pipe
Nenhuma Miniatura disponível
Data
2019-01-01
Autores
Miranda, Eugenio Paceli
Custodio, Tatiana Belo De Sousa
DE LIMA, Francisco Uchoa
Pereira, Taiane Almenda
Bicudo, Andre Luiz Ribeiro [UNESP]
Título da Revista
ISSN da Revista
Título de Volume
Editor
Resumo
The head loss is a fundamental parameter for the dimensioning of the pipes, being directly related to the cost of these pipes, the selection of the pumping system and the energy cost of electricity. That study fitted the Hazen-Williams equation and compared it with the Darcy-Weisbach equation. The performance of the adjusted equation was determined by the concordance index (c), Statistical Standard Error (EPE) and Mean Absolute Error (EAM). The results show that all gridded indices to verify the performance of the adjusted Hazen-Willians equation have improved. The largest difference between the values of continuous load loss. between the Darcy-Weisbach method and the adjusted Hazen-Williams equation was about 0.08%, which can be considered extremely low.
Descrição
Palavras-chave
Darcy-Weisbach, Diameter, Head loss
Como citar
IRRIGA, v. 1, n. 1InovagriSpecialEdition, p. 94-100, 2019.