Three-phase four-wire circuits interpretation by means of different power theories
Abstract
In order to contribute to the discussion of defining a generalized power theory, valid for unbalanced and non linear circuits, this paper discusses the relationship and discrepancies among four modern power theories. Three-phase four-wire circuits, under different conditions, have been analyzed, since the most conflicting and intriguing interpretations take place in case of return conductor occurrence. Simulation results of different load, power supply and line conditions will be discussed in order to elucidate the author's conclusions and to provoke the readers for additional discussions. © 2010 IEEE.
How to cite this document
Marafão, Fernando P. et al. Three-phase four-wire circuits interpretation by means of different power theories. Proceedings of the 2010 10th Conference-Seminar International School on Nonsinusoidal Currents and Compensation, ISNCC 2010, p. 168-173. Available at: <http://hdl.handle.net/11449/71829>.
Keywords
Language
English

Related items
Showing items related by title, author, creator and subject.
-
HPF boost interleaved operating in discontinuous conduction mode for trolleybus application
Gonçalves, Flávio A. S.; Canesin, Carlos A.
; Melo, Guilherme A.
; De Freitas, Luiz C. G.
(2009 Brazilian Power Electronics Conference, COBEP2009, 2009) [Trabalho apresentado em evento]
This paper deals with results of a research and development (R&D) project in cooperation with Electric Power Distribution Company in São Paulo (Brazil) regarding the development and experimental analysis of a new concept ... -
Trolleybus power system for operation with AC or DC distribution networks
Melo, G. A.; Gonçalves, F. A S
; Oliveira, R. N.
; Muno, J. M.; Santos, M.; Canesin, C. A.
(SPEEDAM 2010 - International Symposium on Power Electronics, Electrical Drives, Automation and Motion, 2010) [Trabalho apresentado em evento]
This paper presents the development and experimental analysis of a special input stage converter for a Trolleybus type vehicle allowing its operation in AC (two wires, single-phase) or DC distribution networks. The ... -
Distributed generation modelling for unbalanced three-phase power flow calculations in smart grids
Gallego, Luis A.; Carreno, Edgar; Padilha-Feltrin, Antonio
(2010 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America, T and D-LA 2010, 2011) [Trabalho apresentado em evento]
Distributed Generators (DG) are generally modeled as PQ or PV buses in power flow studies. But in order to integrate DG units into the distribution systems and control the reactive power injection it is necessary to know ...