Atenção!


O atendimento às questões referentes ao Repositório Institucional será interrompido entre os dias 20 de dezembro de 2024 a 5 de janeiro de 2025.

Pedimos a sua compreensão e aproveitamos para desejar boas festas!

 

Comparison of Four Arteries for Invasive Blood Pressure Measurements and Dixtal 2010 Oscillometric Values in Horses Anesthetized With Isoflurane: Does the Artery Matter?

dc.contributor.authorMidon, Monica [UNESP]
dc.contributor.authorYamada, Diego I. [UNESP]
dc.contributor.authorZangirolami Filho, Darcio [UNESP]
dc.contributor.authorSimionato, Giulia C. [UNESP]
dc.contributor.authorFeringer Junior, Walter H. [UNESP]
dc.contributor.authorConde, Gabriel [UNESP]
dc.contributor.authorHofmeister, Erik H.
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionAuburn University
dc.date.accessioned2023-07-29T12:47:19Z
dc.date.available2023-07-29T12:47:19Z
dc.date.issued2023-02-01
dc.description.abstractThis study evaluated the agreement between invasive blood pressure (IBP) values measured in three different arteries and by an oscillometric device (NIBP) with the ones from the transverse facial artery (FA). Six horses (424.2 ± 40.7 kg) were sedated with xylazine (0.6 mg/kg IV), induced with ketamine (2 mg/kg IV) and midazolam (0.1 mg/kg IV), and maintained with isoflurane (1.2 MAC) for 90 minutes in lateral recumbency. FA, auricular artery (AA), lateral digital artery (LDA), and metatarsal artery (MA) were catheterized, and a standard adult cuff was placed on the tail. IBP and NIBP values were recorded at 30, 45, 60, 75, and 90 minutes of anesthesia. Data were analyzed with Shapiro-Wilk and Repeated-Measures Bland-Altman. Values for FA (mm Hg) were 85.4 ± 10.3 for SAP, 70.6 ± 9.3 for MAP, and 58.5 ± 9.5 for DAP. Mean bias and 95% Limit of agreement (LOA) for AA were -1.7 (-29.0 to 25.6), 2.2 (-18.4 to 22.9), 1.9 (-18.2 to 22.0), for LDA: 1.4 (-25.1 to 27.8), 2.9 (-19.3 to 25.0), 2.3 (-18.4 to 22.9), for MA: -3.2 (-28.3 to 22.0), 2.7 (-16.6 to 22.1), 4.9 (-13.8 to 22.2), and for NIBP: -5.7 (-28.3 to 16.9), 7.9 (-9.5 to 25.3), 17.2 (-2.4 to 36.8), for SAP, MAP and DAP respectively. There is a reasonable bias for IBP values among the arteries evaluated, however a wide LOA, demonstrating the arteries are not interchangeable. NIBP method from Dixtal 2010 results in inaccurate blood pressure values in horses.en
dc.description.affiliationSchool of Agrarian and Veterinary Science – FCAV Sao Paulo State University - UNESP, São Paulo
dc.description.affiliationDepartment of Clinical Sciences College of Veterinary Medicine Auburn University
dc.description.affiliationUnespSchool of Agrarian and Veterinary Science – FCAV Sao Paulo State University - UNESP, São Paulo
dc.identifierhttp://dx.doi.org/10.1016/j.jevs.2023.104219
dc.identifier.citationJournal of Equine Veterinary Science, v. 121.
dc.identifier.doi10.1016/j.jevs.2023.104219
dc.identifier.issn0737-0806
dc.identifier.scopus2-s2.0-85146452893
dc.identifier.urihttp://hdl.handle.net/11449/246670
dc.language.isoeng
dc.relation.ispartofJournal of Equine Veterinary Science
dc.sourceScopus
dc.subjectAnesthesia
dc.subjectBlood pressure
dc.subjectEquine
dc.subjectMonitoring
dc.titleComparison of Four Arteries for Invasive Blood Pressure Measurements and Dixtal 2010 Oscillometric Values in Horses Anesthetized With Isoflurane: Does the Artery Matter?en
dc.typeArtigo
unesp.author.orcid0000-0002-7867-4991[2]
unesp.author.orcid0000-0002-6360-3912[7]

Arquivos

Coleções