Right-to-left shunt determination in dog lungs under inhalation anesthesia with rebreathing and non-rebreathing system

dc.contributor.authorRosa, André Leguthe
dc.contributor.authorMota, Patrícia Cristina Azevedo
dc.contributor.authorCastiglia, Yara Marcondes Machado [UNESP]
dc.contributor.institutionSão Paulo Methodistic University School of Veterinary Medicine
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T15:13:56Z
dc.date.available2014-05-20T15:13:56Z
dc.date.issued2006-12-01
dc.description.abstractOBJETIVO: Comparar a formação de shunt venoso-arterial em pulmões de cães submetidos a anestesia geral inalatória utilizando-se sistemas de anestesia com e sem reinalação, com fração inspirada de oxigênio de 0,4 e 0,9, respectivamente. MÉTODOS: Empregaram-se 20 cães induzidos com tiopental sódico (30mg/kg) e mantidos com sevoflurano (3%) e alocados em dois grupos (n=10); os animais de GI foram ventilados com modalidade controlada em sistema semifechado, sem reinalação, F I O2 = 0,9, e os de GII, com modalidade controlada, sistema semifechado, com reinalação e F I O2 = 0,4. Os atributos analisados durante o experimento foram: freqüência cardíaca, pressão arterial média, shunt pulmonar venoso-arterial, hematócrito, hemoglobina, pressão parcial de oxigênio arterial, pressão parcial de oxigênio no sangue venoso misto, saturação de oxigênio no sangue venoso misto, pressão parcial de dióxido de carbono arterial e pressão de vapor de água nos alvéolos (P VA). RESULTADOS: A P VA foi significativamente maior em GII. A análise estatística dos valores encontrados de shunt mostrou que GI e GII apresentaram diferenças significativas, sendo que os resultados de GI são maiores que os de GII em todos os momentos avaliados. Já a análise de momentos dentro de um mesmo grupo não demonstrou diferenças. CONCLUSÃO: O sistema de anestesia sem reinalação com F I O2 = 0,9 desenvolveu maior grau de shunt pulmonar venoso-arterial que o sistema de anestesia com reinalação e F I O2 = 0,4. A umidificação dos gases em GII contribuiu para diminuir o shunt.pt
dc.description.abstractPURPOSE: To investigatge right-to-left shunt determination in dog lungs under inhalantion anesthesia with non-rebreathing and rebreathing systems and fraction of inspired oxygen (F I O2) of 0.9 and 0.4, respectively. METHODS: Two groups of 10 dogs each under inhalation anesthesia with sevoflurane: GI in which it was utilized non-rebreathing semiclosed system and F I O2 = 0.9, and GII in which it was utilized rebreathing semiclosed system and F I O2 = 0.4. The study parameters were: heart rate, medium arterial pressure, right-to-left intrapulmonary shunt, hematocrit, hemoglobin, arterial partial pressure of oxygen, mixed venous partial pressure of oxygen, mixed venous oxygen saturation, arterial partial pressure of carbon dioxide, partial pressure of water in the alveoli. RESULTS: Shunt results were significantly different between the two groups - GI data were higher than GII in all the evaluated moments. Hence, the group with nonrebreathing (GI) developed a superior grade of intrapulmonary shunt when compared with the rebreathing group (GII). The partial pressure of water in the alveoli was significantly higher in GII. CONCLUSION: The inhalation anesthesia with non-rebreathing system and F I O2 = 0.9 developed a higher grade of intrapulmonary right-to-left shunt when compared with the rebreathing system and F I O2 = 0.4. The higher humidity in GII contributed to the result.en
dc.description.affiliationSão Paulo Methodistic University School of Veterinary Medicine
dc.description.affiliationUNESP Department of Anesthesiology
dc.description.affiliationUnespUNESP Department of Anesthesiology
dc.format.extent374-379
dc.identifierhttp://dx.doi.org/10.1590/S0102-86502006000600004
dc.identifier.citationActa Cirúrgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 21, n. 6, p. 374-379, 2006.
dc.identifier.doi10.1590/S0102-86502006000600004
dc.identifier.fileS0102-86502006000600004.pdf
dc.identifier.issn0102-8650
dc.identifier.scieloS0102-86502006000600004
dc.identifier.urihttp://hdl.handle.net/11449/28997
dc.language.isoeng
dc.publisherSociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
dc.relation.ispartofActa Cirúrgica Brasileira
dc.relation.ispartofjcr0.933
dc.relation.ispartofsjr0,395
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectAnestesia por Inalaçãopt
dc.subjectAnestesia com Circuito Fechadopt
dc.subjectAtelectasiapt
dc.subjectCãespt
dc.subjectAnesthesiaen
dc.subjectInhalationen
dc.subjectAnesthesiaen
dc.subjectClosed-Circuiten
dc.subjectAtelectasisen
dc.subjectDogsen
dc.titleRight-to-left shunt determination in dog lungs under inhalation anesthesia with rebreathing and non-rebreathing systemen
dc.title.alternativeDeterminação de shunt venoso-arterial em pulmões de cães sob anestesia geral inalatória por sistemas com e sem reinalaçãopt
dc.typeArtigo
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Medicina, Botucatupt
unesp.departmentAnestesiologia - FMBpt

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0102-86502006000600004.pdf
Tamanho:
188.81 KB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: