Desenvolvimento de superfícies nanoestruturadas capacitivas e eletroquimicamente ativas para aplicações em diagnóstico clínico

dc.contributor.advisorBueno, Paulo Roberto [UNESP]
dc.contributor.advisorBedatty Fernandes, Flávio Cesar
dc.contributor.authorOliveira, Raphael Mazzine Barbosa
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-09-05T12:38:02Z
dc.date.available2018-09-05T12:38:02Z
dc.date.issued2018-08-21
dc.description.abstractDesde a primeira descrição de biossensor reportada por Clark e Lyons em 1962, houve um extenso trabalho no desenvolvimento e aprimoramento de novas técnicas de biossensoriamento para detecção de biomarcadores com relevância médica. Destaca-se nesse processo o estudo de superfície de eletrodos, pois esse influencia diretamente em aspectos como; sensibilidade, estabilidade e qualidade do sinal. Portanto, este projeto consiste em avaliar comparativamente três superfícies de eletrodos baseadas em nanoestruturas contendo nanopartículas de azul da Prússia, funcionando com sonda redox do sistema, e materiais carbonáceos (como óxido de grafeno e nanotubos de carbono) para aplicação em biossensores. Foram avaliados aspectos como composição, características capacitivas redox e estabilidade de sinal. A técnica de análise utilizada é a espectroscopia de capacitância eletroquímica (ECE) que apresenta vantagens como não usar amplificadores de sinal (sondas redox) em solução, configuração esta, importante para métodos de diagnóstico point-of-care. Das superfícies analisadas, a composta por nanopartículas de azul da Prússia e óxido de grafeno (PBNP+GO) apresentou os melhores parâmetros de estabilidade e compatibilidade com os aspectos teóricos da técnica de ECE, sendo então selecionada para realização de testes de biossensoriamento que, através da funcionalização da superfície com anticorpos Anti-IL-6, detectaram seletivamente a presença do biomarcador IL-6.pt
dc.description.abstractSince the first description of biosensor reported by Clark and Lyons in 1962, numerous works related to the development and enhancement of novel medical biosensing techniques have been published. In that context, it must be highlighted the study of electrode surfaces as it has direct influence in aspects like; sensitivity, stability and signal quality. Therefore, this project aims to evaluate three electrode surfaces based on nanostructures with Prussian blue nanoparticles, as redox probe, and carbonaceous materials (like graphene oxide and carbon nanotubes) and their application in biosensors. It was evaluated aspects like composition, redox capacitive characteristics and signal stability. The electrochemical capacitance spectroscopy technique (ECE) was used as it offers several advantages like no need of signal amplifiers (redox probes) in solution and, then, making this technique more adequate for point-of-care diagnosis. Among the analysed surfaces, the one composed by Prussian blue nanoparticles and graphene oxide (PBNP+GO) was identified as the best surface in terms of stability and compatibility to the theoretical aspects of ECE. Therefore, that structure was selected to further biosensing essays, by functionalizing the surface with Anti-IL-6 antibodies, that indicated the selective detection of the IL-6 biomarker.en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipId1583843
dc.identifier.aleph000907502
dc.identifier.capes33004030072P8
dc.identifier.lattes0477045906733254
dc.identifier.orcid0000-0003-2827-0208
dc.identifier.urihttp://hdl.handle.net/11449/155900
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso aberto
dc.subjectBiossensor eletroquímicopt
dc.subjectBiosensor Capacitivopt
dc.subjectGrafenopt
dc.subjectAzul da Prússiapt
dc.subjectEspectroscopia de Capacitância Eletroquímicapt
dc.subjectElectrochemical Biosensoren
dc.subjectCapacitive Biosensoren
dc.subjectGrapheneen
dc.subjectPrussian Blueen
dc.subjectElectrochemical Capacitance Spectroscopyen
dc.titleDesenvolvimento de superfícies nanoestruturadas capacitivas e eletroquimicamente ativas para aplicações em diagnóstico clínicopt
dc.title.alternativeDevelopment of capacitive and electrochemical active nanostructured surfaces for application in clinical diagnosticsen
dc.typeDissertação de mestrado
unesp.advisor.lattes0477045906733254[1]
unesp.advisor.orcid0000-0003-2827-0208[1]
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Química, Araraquarapt
unesp.embargoOnlinept
unesp.graduateProgramQuímica - IQAR 33004030072P8pt
unesp.knowledgeAreaQuímicapt
unesp.researchAreaEletroquímica e eletroanalíticapt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
oliveira_rmb_me_araiq_int.pdf
Tamanho:
2.09 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
3.03 KB
Formato:
Item-specific license agreed upon to submission
Descrição: