Primary tooth length determination in direct digital radiography: An in vivo study

dc.contributor.authorSantos-Pinto, Lourdes Aparecida Martins dos [UNESP]
dc.contributor.authorLoiola Cordeiro, Rita de Cassia [UNESP]
dc.contributor.authorCilense Zuanon, Angela Cristina [UNESP]
dc.contributor.authorBasso, Maria Daniela
dc.contributor.authorGonçalves, Marcelo [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniv Franca UNIFRAN
dc.contributor.institutionW Parana Univ UNIOEST
dc.date.accessioned2014-02-26T17:02:07Z
dc.date.accessioned2014-05-20T13:44:42Z
dc.date.available2014-02-26T17:02:07Z
dc.date.available2014-05-20T13:44:42Z
dc.date.issued2007-11-01
dc.description.abstractPurpose: the purpose of this in vivo study was to compare the accuracy of primary incisor length determined by direct digital radiography (straight-line measurement and grid superimposition) and measurement of the actual tooth length. Methods. Twenty-two primary maxillary incisors that required extractions were selected from 3- to 5-year-old children. The teeth were radiographed with an intraoral sensor using the long cone technique and a sensor holder (30-cm focus-to-sensor distance). The exposure time was 03 seconds. Tooth length was estimated by using straight-line and grid measurements provided by the distance measurement feature of the Computed Dental Radiography digital dental imaging system. The actual tooth length was obtained by measuring the extracted tooth with G digital caliper. Data were analyzed statistically by Pearson's correlation coefficient and a paired t test. Results: There were statistically significant differences (P=.007) between the 2 measurement techniques and between the actual tooth lengths and grid measurements. There was no statistically significant difference (P=38) between straight-line measurements and actual tooth lengths, showing that the straight-line measurements were more accurate. Underestimation of the actual tooth length, however, occurred in 45% of the straight-line measurements and in 73% of the grid measurements. Conclusion: It is possible to determine primary tooth length in digital radiographs using onscreen measurements with 0 reasonable degree of accuracy.en
dc.description.affiliationSão Paulo State Univ, UNESP, Dept Pediat Dent, Sch Dent Araraquara, São Paulo, Brazil
dc.description.affiliationUniv Franca UNIFRAN, Sch Dent Franca, Dept Pediat Dent, São Paulo, Brazil
dc.description.affiliationW Parana Univ UNIOEST, Sch Dent Cascavel, Dept Pediat Dent, Parana, Brazil
dc.description.affiliationUnespSão Paulo State Univ, UNESP, Dept Pediat Dent, Sch Dent Araraquara, São Paulo, Brazil
dc.format.extent470-474
dc.identifierhttp://www.ingentaconnect.com/content/aapd/pd/2007/00000029/00000006/art00005
dc.identifier.citationPediatric Dentistry. Chicago: Amer Acad Pediatric Dentistry, v. 29, n. 6, p. 470-474, 2007.
dc.identifier.issn0164-1263
dc.identifier.lattes8185082796673527
dc.identifier.lattes8672541377335694
dc.identifier.lattes1067437159861527
dc.identifier.orcid0000-0003-2386-842X
dc.identifier.urihttp://hdl.handle.net/11449/15676
dc.identifier.wosWOS:000253500400005
dc.language.isoeng
dc.publisherAmer Acad Pediatric Dentistry
dc.relation.ispartofPediatric Dentistry
dc.relation.ispartofsjr0,630
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectcomputer-assisted imaging processingpt
dc.subjectdiagnostic imagingpt
dc.subjectdigital radiographypt
dc.subjectprimary toothpt
dc.subjecttooth lengthpt
dc.titlePrimary tooth length determination in direct digital radiography: An in vivo studyen
dc.typeArtigo
dcterms.rightsHolderAmer Acad Pediatric Dentistry
unesp.author.lattes8185082796673527
unesp.author.lattes8672541377335694[3]
unesp.author.lattes1067437159861527
unesp.author.orcid0000-0003-2386-842X[1]
unesp.author.orcid0000-0003-3131-0805[3]
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Odontologia, Araraquarapt
unesp.departmentClínica Infantil - FOARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: