Effect of etching temperature on surface properties of Ti6Al4V alloy for use in biomedical applications
dc.contributor.author | Alberti, Charles Jourdan [UNESP] | |
dc.contributor.author | Saito, Eduardo | |
dc.contributor.author | De Freitas, Filipe Estevão | |
dc.contributor.author | Reis, Danieli Aparecida Pereira | |
dc.contributor.author | MacHado, João Paulo Barros | |
dc.contributor.author | Dos Reis, Adriano Gonçalves [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade Federal de São Paulo (UNIFESP) | |
dc.contributor.institution | Instituto Nacional de Pesquisas Espaciais | |
dc.date.accessioned | 2020-12-12T01:22:06Z | |
dc.date.available | 2020-12-12T01:22:06Z | |
dc.date.issued | 2019-01-01 | |
dc.description.abstract | The objective of this study is to evaluate the surface physicochemical properties of Ti6Al4V alloy after etching with a piranha's solution at temperatures of 25 °C, 40 °C, and 60 °C for 30 min. Scanning electron microscopy with energy-dispersive X-ray spectroscopy, optical profilometry, X-ray diffraction, and wettability analyses were used to characterize the surface of the samples. In addition, corrosion tests were performed using potentiodynamic polarization and electrochemical impedance spectroscopy. The proposed surface treatment did not alter the wettability and surface chemistry (crystallinity), but the texture, surface roughness, superficial area, and corrosion resistance of the alloy could be changed by varying the etching temperature. Considering that these properties are indirect indicators of the alloy's potential success in the osseointegration of a dental implant, the surface treatment of the Ti6Al4V alloy using a piranha solution while controlling the etching temperature has attractive biomedical applications. | en |
dc.description.affiliation | Instituto de Ciência e Tecnologia Universidade Estadual Paulista (Unesp) | |
dc.description.affiliation | Instituto de Ciência e Tecnologia Universidade Federal de São Paulo | |
dc.description.affiliation | Laboratório Associado de Sensores e Materiais Instituto Nacional de Pesquisas Espaciais | |
dc.description.affiliationUnesp | Instituto de Ciência e Tecnologia Universidade Estadual Paulista (Unesp) | |
dc.identifier | http://dx.doi.org/10.1590/1980-5373-MR-2018-0782 | |
dc.identifier.citation | Materials Research, v. 22. | |
dc.identifier.doi | 10.1590/1980-5373-MR-2018-0782 | |
dc.identifier.file | S1516-14392019000700270.pdf | |
dc.identifier.issn | 1980-5373 | |
dc.identifier.issn | 1516-1439 | |
dc.identifier.scielo | S1516-14392019000700270 | |
dc.identifier.scopus | 2-s2.0-85084184530 | |
dc.identifier.uri | http://hdl.handle.net/11449/198792 | |
dc.language.iso | eng | |
dc.relation.ispartof | Materials Research | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Scopus | |
dc.subject | Chemical etching | |
dc.subject | Corrosion resistance | |
dc.subject | Surface modification | |
dc.subject | Temperature | |
dc.subject | Ti6Al4V | |
dc.title | Effect of etching temperature on surface properties of Ti6Al4V alloy for use in biomedical applications | en |
dc.type | Artigo |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- S1516-14392019000700270.pdf
- Tamanho:
- 8.21 MB
- Formato:
- Adobe Portable Document Format