Microwave Disinfection of Complete Dentures Contaminated In Vitro with Selected Bacteria
dc.contributor.author | Dovigo, Lívia Nordi [UNESP] | |
dc.contributor.author | Pavarina, Ana Claudia [UNESP] | |
dc.contributor.author | Ribeiro, Daniela Garcia [UNESP] | |
dc.contributor.author | de Oliveira, Juliana Aparecida | |
dc.contributor.author | Vergani, Carlos Eduardo [UNESP] | |
dc.contributor.author | Machado, Ana Lucia [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T13:46:35Z | |
dc.date.available | 2014-05-20T13:46:35Z | |
dc.date.issued | 2009-10-01 | |
dc.description.abstract | Purpose: This study evaluated the effectiveness of microwave irradiation for disinfection of simulated complete dentures.Materials and Methods: Seventy dentures were fabricated in a standardized procedure, subjected to ethylene oxide sterilization, individually inoculated (10(7) cfu/mL) with Staphylococcus aureus (n = 20), Pseudomona aeruginosa (n = 20), and Bacillus subtilis (n = 30) and incubated for 24 hours at 37 degrees C. After that, 40 dentures were selected for microwaving. For each microorganism, 10 dentures were submitted to microwave irradiation at 650 W for 3 minutes. In addition, 10 dentures contaminated with B. subtilis were irradiated for 5 minutes. Thirty non-microwaved dentures (n = 10 for each bacteria) were used as positive controls. Replicate aliquots (25 mu L) of suspensions were plated at dilutions of 10(-3) to 10(-6) on plates of selective media appropriate for each organism. After incubation (37 degrees C for 48 hours), colonies were counted (cfu/mL). TSB beakers with the microwaved dentures were incubated at 37 degrees C for a further 7 days to verify long-term disinfection. The data were statistically analyzed by the Kruskal-Wallis test (alpha = 0.05).Results: No evidence of growth was observed at 48 hours for S. aureus and P. aeruginosa on plates, and no turbidity was visible in the TSB beakers of these specimens after 7 days of incubation. Dentures contaminated with B. subtilis and irradiated for 3 minutes produced microbial growth on six plates and turbidity on all TSB beakers. Microwaving for 5 minutes resulted in survival of B. subtilis in two plates and two beakers.Conclusion: Microwave irradiation for 3 minutes at 650 W produced sterilization of complete dentures contaminated with S. aureus and P. aeruginosa. Dentures contaminated with B. subtilis were disinfected by microwave irradiation after 3 and 5 minutes at 650 W. | en |
dc.description.affiliation | São Paulo State Univ, UNESP, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, São Paulo, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ, UNESP, Araraquara Dent Sch, Dept Dent Mat & Prosthodont, São Paulo, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorshipId | FAPESP: 05/02384-4 | |
dc.format.extent | 611-617 | |
dc.identifier | http://dx.doi.org/10.1111/j.1532-849X.2009.00489.x | |
dc.identifier.citation | Journal of Prosthodontics-implant Esthetic and Reconstructive Dentistry. Malden: Wiley-blackwell, v. 18, n. 7, p. 611-617, 2009. | |
dc.identifier.doi | 10.1111/j.1532-849X.2009.00489.x | |
dc.identifier.issn | 1059-941X | |
dc.identifier.lattes | 8867670539105403 | |
dc.identifier.lattes | 3003130522427820 | |
dc.identifier.lattes | 8000248781842587 | |
dc.identifier.lattes | 0127570480681342 | |
dc.identifier.orcid | 0000-0002-7375-4714 | |
dc.identifier.uri | http://hdl.handle.net/11449/16499 | |
dc.identifier.wos | WOS:000207914700009 | |
dc.language.iso | eng | |
dc.publisher | Wiley-Blackwell | |
dc.relation.ispartof | Journal of Prosthodontics-implant Esthetic and Reconstructive Dentistry | |
dc.relation.ispartofjcr | 1.745 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | Disinfection | en |
dc.subject | microwaves | en |
dc.subject | complete denture | en |
dc.subject | infection control | en |
dc.title | Microwave Disinfection of Complete Dentures Contaminated In Vitro with Selected Bacteria | en |
dc.type | Artigo | |
dcterms.license | http://olabout.wiley.com/WileyCDA/Section/id-406071.html | |
dcterms.rightsHolder | Wiley-blackwell | |
unesp.author.lattes | 8867670539105403[2] | |
unesp.author.lattes | 3003130522427820[5] | |
unesp.author.lattes | 8000248781842587[6] | |
unesp.author.lattes | 0127570480681342 | |
unesp.author.orcid | 0000-0002-7375-4714[5] | |
unesp.author.orcid | 0000-0002-9231-1994[2] | |
unesp.author.orcid | 0000-0002-2718-428X[6] | |
unesp.campus | Universidade Estadual Paulista (Unesp), Faculdade de Odontologia, Araraquara | pt |
unesp.department | Materiais Odontológicos e Prótese - FOAR | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: