Optimal phasor measurement units placement for fault location on overhead electric power distribution feeders

dc.contributor.authorBíscaro, A. A P [UNESP]
dc.contributor.authorPereira, R. A F [UNESP]
dc.contributor.authorMantovani, J. R S [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:25:53Z
dc.date.available2014-05-27T11:25:53Z
dc.date.issued2011-05-31
dc.description.abstractThis paper proposes a new approach for optimal phasor measurement units placement for fault location on electric power distribution systems using Greedy Randomized Adaptive Search Procedure metaheuristic and Monte Carlo simulation. The optimized placement model herein proposed is a general methodology that can be used to place devices aiming to record the voltage sag magnitudes for any fault location algorithm that uses voltage information measured at a limited set of nodes along the feeder. An overhead, three-phase, three-wire, 13.8 kV, 134-node, real-life feeder model is used to evaluate the algorithm. Tests show that the results of the fault location methodology were improved thanks to the new optimized allocation of the meters pinpointed using this methodology. © 2011 IEEE.en
dc.description.affiliationUNESP-Univ. Estadual Paulista FEIS Electrical Engineering Department, Ilha Solteira, São Paulo, 15385-000
dc.description.affiliationUnespUNESP-Univ. Estadual Paulista FEIS Electrical Engineering Department, Ilha Solteira, São Paulo, 15385-000
dc.format.extent37-43
dc.identifierhttp://dx.doi.org/10.1109/TDC-LA.2010.5762858
dc.identifier.citation2010 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America, T and D-LA 2010, p. 37-43.
dc.identifier.doi10.1109/TDC-LA.2010.5762858
dc.identifier.lattes0614021283361265
dc.identifier.scopus2-s2.0-79957548651
dc.identifier.urihttp://hdl.handle.net/11449/72441
dc.language.isoeng
dc.relation.ispartof2010 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America, T and D-LA 2010
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectfault location
dc.subjectMonte Carlo methods and optimization methods
dc.subjectOptimal allocation
dc.subjectphasor measurement units (PMUs)
dc.subjectElectric power
dc.subjectElectric power distribution systems
dc.subjectFault location
dc.subjectFault location algorithms
dc.subjectGeneral methodologies
dc.subjectGreedy randomized adaptive search procedure
dc.subjectMetaheuristic
dc.subjectMonte Carlo Simulation
dc.subjectOptimized allocation
dc.subjectPhasor measurement unit
dc.subjectPlacement model
dc.subjectVoltage sags
dc.subjectAlgorithms
dc.subjectComputer simulation
dc.subjectElectric load distribution
dc.subjectElectric power distribution
dc.subjectElectric power system interconnection
dc.subjectElectric power transmission
dc.subjectFeeding
dc.subjectOptimization
dc.subjectPhase measurement
dc.subjectThermoelectric equipment
dc.subjectUnits of measurement
dc.subjectMonte Carlo methods
dc.titleOptimal phasor measurement units placement for fault location on overhead electric power distribution feedersen
dc.typeTrabalho apresentado em evento
dcterms.licensehttp://www.ieee.org/publications_standards/publications/rights/rights_policies.html
unesp.author.lattes0614021283361265
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Engenharia, Ilha Solteirapt
unesp.departmentEngenharia Elétrica - FEISpt

Arquivos