Influence of the addition of synthetic termite saliva in the compressive strength and water absorption of compacted soil-cement

dc.contributor.authorFaria, Obede Borges
dc.contributor.authorBattistelle, Rosane Aparecida Gomes
dc.contributor.authorNeves, Célia
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionRede Ibero-americana PROTERRA
dc.date.accessioned2018-11-12T17:27:02Z
dc.date.available2018-11-12T17:27:02Z
dc.date.issued2016-09-01
dc.description.abstractAbstract The aim of this paper is to determine the effect of adding 0.1 wt% of synthetic termite saliva on a fine and clayey sand latosol (76.5% sand) from the region of Bauru, SP (Brazil), stabilized with 1% to 3% of cement. Compacted cylindrical specimens (with standard Proctor energy) were tested to determine their compressive strength and water absorption. The results indicate that the use of the chemical stabilizer increased by at least 35% the compressive strength and reduced by up to 13% the water absorption of the samples. This work contributes to efforts aimed at reducing the consumption of cement through the production of stabilized compressed earth blocks and bricks (CEB) and rammed earth.en
dc.description.abstractResumo Este trabalho apresenta um estudo realizado para avaliar o efeito da adição de 0,1% em massa de baba de cupim sintética em um latossolo arenoargiloso fino (76,5% de areia), proveniente da região de Bauru, SP, Brasil, estabilizado com 1% a 3% de cimento. Foram ensaiados corpos de prova cilíndricos (compactados com energia Proctor normal) para determinar sua resistência à compressão e sua absorção de água. Os resultados indicam que o uso do aditivo produziu aumento de pelo menos 35% na resistência à compressão e reduziu em até 13% a absorção de água das amostras. O trabalho contribui com os esforços de redução do consumo de cimento na construção civil, através da produção de blocos (e tijolos) de terra comprimida (BTC) estabilizada e taipa.pt
dc.description.affiliationUniversidade Estadual Paulista Júlio de Mesquita Filho
dc.description.affiliationRede Ibero-americana PROTERRA
dc.description.affiliationUnespUniversidade Estadual Paulista Júlio de Mesquita Filho
dc.format.extent127-136
dc.identifierhttp://dx.doi.org/10.1590/s1678-86212016000300096
dc.identifier.citationAmbiente Construído. Associação Nacional de Tecnologia do Ambiente Construído - ANTAC, v. 16, n. 3, p. 127-136, 2016.
dc.identifier.doi10.1590/s1678-86212016000300096
dc.identifier.fileS1678-86212016000300127.pdf
dc.identifier.issn1678-8621
dc.identifier.scieloS1678-86212016000300127
dc.identifier.urihttp://hdl.handle.net/11449/157807
dc.language.isoeng
dc.publisherAssociação Nacional de Tecnologia do Ambiente Construído - ANTAC
dc.relation.ispartofAmbiente Construído
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectEarthen architecture and constructionen
dc.subjectCompacted soil-cementen
dc.subjectSynthetic termite salivaen
dc.subjectCompressive strengthen
dc.subjectWater absorptionen
dc.subjectArquitetura e construção com terrapt
dc.subjectSolo-cimento compactadopt
dc.subjectBaba de cupim sintéticapt
dc.subjectResistência à compressãopt
dc.subjectAbsorção de águapt
dc.titleInfluence of the addition of synthetic termite saliva in the compressive strength and water absorption of compacted soil-cementen
dc.title.alternativeInfluência da adição de baba de cupim sintética na resistência à compressão e absorção de água de solo-cimento compactadopt
dc.typeArtigo

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S1678-86212016000300127.pdf
Tamanho:
525.38 KB
Formato:
Adobe Portable Document Format

Coleções