dc.description.abstractQuando da utilização de bloqueadores neuromusculares, já foi enfatizado na literatura médica humana, que é de vital imporância a monitoração do bloqueio neuromuscular e que estes agentes nunca devem ser utilizados sem a mesma. O objetivo deste estudo foi o de avaliar o uso do monitor da transmissão neuromuscular TOF-Guard em eqüinos. Para tanto, doze eqüinos foram separados aleatoriamente para receberem como bloqueadores neuromusculares o pancurônio ou o atracúrio. Todos os eqüinos foram pré-medicados com romifidina, induzidos com diazepam e quetamina e mantidos com halotano. Foi administrado o atracúrio ou o pancurônio, seguindo-se a apnéia e início da ventilação mecânica controlada. O tempo entre a administração do relaxante muscular e a obtenção de um bloqueio máximo (T1=0), o retorno do T1 para 25% e da razão do TOF para 0,7 e o tempo do retorno do T1 de 25 para 75% foram mensurados. Concluiu-se que é de grande importância a monitoração do bloqueio neuromuscular quando da utilização de um bloqueador neuromuscular não-despolarizante, uma vez que ela torna o ato anestésico e cirúrgico mais seguro, com a utilização de doses adequadas que inviabilizam a superficialização do bloqueio durante o procedimento cirúrgico. O monitor TOF-Guard mostrou ser uma boa opção para a monitoração do bloqueio neuromuscular em eqüinos.pt
dc.description.abstractIt has been emphasized in the human medical literature, that when using a neuromuscular blocking agent, it is of vital importance the monitoring of the neuromuscular block and that these agents should never be used without it. The purpose of this study was to evaluate the use of the neuromuscular transmission monitor TOF-Guard in horses. Twelve horses were randomly assigned whether to receive pancuronium or atracurium as the neuromuscular blocking agent. All horses were pre-medicated with romifidine, anaesthesia induced with diazepam and ketamine and maintenance with halothane. Abolition of spontaneous ventilation was accomplished by the administration of atracurium or pancuronium. The time from injection of the muscle relaxant agent to the onset of maximum block (T1=0), recovery of T1 to 25% and the recovery of TOF ratio to 0.7 were recorded, as was the time for recovery of T1 from 25 to 75%. It was concluded that it is very important the neuromuscular transmission monitoring during the use of a nondepolarizing neuromuscular blocking agent, since it provides a safer anaesthetic and surgical procedure with the use of adequate dosages and due to the impossibility of a superficialization of the neuromuscular blockade during a surgical procedure. The TOF-Guard showed to be a good option for neuromuscular monitoring in horses.en
dc.description.affiliationUniversidade Estadual de São Paulo Faculdade de Ciências Agrárias e Veterinárias
dc.description.affiliationUniversidade de São Paulo Faculdade de Medicina Veterinária e Zootecnia
dc.format.extent57-62
dc.identifierhttp://dx.doi.org/10.1590/S0103-84781999000100011
dc.identifier.citationCiência Rural. Universidade Federal de Santa Maria (UFSM), v. 29, n. 1, p. 57-62, 1999.
dc.identifier.doi10.1590/S0103-84781999000100011
dc.identifier.fileS0103-84781999000100011.pdf
dc.identifier.issn0103-8478
dc.identifier.scieloS0103-84781999000100011
dc.identifier.urihttp://hdl.handle.net/11449/1640
dc.language.isoeng
dc.publisherUniversidade Federal de Santa Maria (UFSM)
dc.relation.ispartofCiência Rural
dc.relation.ispartofjcr0.525
dc.relation.ispartofsjr0,337
dc.rights.accessRightsAcesso aberto
dc.sourceSciELO
dc.subjectbloqueadores neuromuscularespt
dc.subjectmonitor da transmissão neuromuscularpt
dc.subjectTOF-Guardpt
dc.subjecteqüinospt
dc.subjectneuromuscular blocking agentsen
dc.subjectneuromuscular transmission monitoren
dc.subjectTOF-Guarden
dc.subjecthorsesen
dc.titleThe tof-guard neuromuscular transmission monitor and its use in horsesen
dc.title.alternativeO monitor da transmissão neuromuscular tof-guard e seu uso em eqüinospt
dc.typeArtigo

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0103-84781999000100011.pdf
Tamanho:
466.7 KB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 2 de 2
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções