Regeneration of poly-L-lysine modified carbon electrodes in the accumulation and cathodic stripping voltammetric determination of the cromoglycate anion
dc.contributor.author | Pereira, F. C. | |
dc.contributor.author | Fogg, A. G. | |
dc.contributor.author | Zanoni, Maria Valnice Boldrin [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Univ Luton | |
dc.contributor.institution | Loughborough Univ Technol | |
dc.date.accessioned | 2014-05-20T15:27:04Z | |
dc.date.available | 2014-05-20T15:27:04Z | |
dc.date.issued | 2003-07-27 | |
dc.description.abstract | Cromoglycate is accumulated on a poly-L-lysine (PLL) modified carbon electrode best from pH 4 solution, where it is anionic and the PLL is cationic, and at which pH the cromoglycate gives a good reduction peak at -0.82 V. The PLL film can be regenerated readily by washing the electrode with 3 M sodium hydroxide solution, in which the PLL is deprotonated. Regeneration of the film is not required as frequently when larger amounts of PLL are incorporated into it. This allows standard addition procedures to be carried out without regenerating the electrode. Linear calibration graphs have been obtained typically in the range 0.1 - 1.5 mug ml(-1). Detection limits have been calculated to be 10 ng ml(-1). The standard addition method has been applied satisfactorily to diluted urine solutions. (C) 2003 Elsevier B.V. B.V. All rights reserved. | en |
dc.description.affiliation | Univ Estadual Paulista, Inst Quim, Dept Quim Analt, BR-14801970 Araraquara, SP, Brazil | |
dc.description.affiliation | Univ Luton, Luton Inst, Luton LU1 5DU, Beds, England | |
dc.description.affiliation | Loughborough Univ Technol, Loughborough LE11 3TU, Leics, England | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Inst Quim, Dept Quim Analt, BR-14801970 Araraquara, SP, Brazil | |
dc.format.extent | 1023-1032 | |
dc.identifier | http://dx.doi.org/10.1016/S0039-9140(03)00181-4 | |
dc.identifier.citation | Talanta. Amsterdam: Elsevier B.V., v. 60, n. 5, p. 1023-1032, 2003. | |
dc.identifier.doi | 10.1016/S0039-9140(03)00181-4 | |
dc.identifier.issn | 0039-9140 | |
dc.identifier.orcid | 0000-0002-2296-1393 | |
dc.identifier.uri | http://hdl.handle.net/11449/37125 | |
dc.identifier.wos | WOS:000184367700017 | |
dc.language.iso | eng | |
dc.publisher | Elsevier B.V. | |
dc.relation.ispartof | Talanta | |
dc.relation.ispartofjcr | 4.244 | |
dc.relation.ispartofsjr | 1,186 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | poly-L-lysine | pt |
dc.subject | sodium cromoglycate | pt |
dc.subject | modified electrodes | pt |
dc.subject | electroanalysis | pt |
dc.title | Regeneration of poly-L-lysine modified carbon electrodes in the accumulation and cathodic stripping voltammetric determination of the cromoglycate anion | en |
dc.type | Artigo | |
dcterms.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dcterms.rightsHolder | Elsevier B.V. | |
unesp.author.orcid | 0000-0002-2296-1393[3] | |
unesp.campus | Universidade Estadual Paulista (Unesp), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |
Arquivos
Licença do Pacote
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: