Determination of VO2-Intensity Relationship and MAOD in Tethered Swimming

dc.contributor.authorKalva-Filho, C. A.
dc.contributor.authorAraujo, M. Y. C. [UNESP]
dc.contributor.authorSilva, A.
dc.contributor.authorGobatto, C. A.
dc.contributor.authorZagatto, A. M. [UNESP]
dc.contributor.authorGobbi, R. B.
dc.contributor.authorPapoti, M.
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Estadual de Campinas (UNICAMP)
dc.date.accessioned2018-11-26T16:54:48Z
dc.date.available2018-11-26T16:54:48Z
dc.date.issued2016-08-01
dc.description.abstractThis study aimed to test the reproducibility of the maximal accumulated oxygen deficit (MAOD) values and VO2-intensity relationship parameters as measured during tethered swimming. 9 swimmers performed an incremental test to determine the maximal aerobic force (MAF), 6 submaximal efforts to develop VO2-intensity relationship, and an exhaustive effort to determine MAOD. The tests were performed twice. The reproducibility of the measurements was tested using intraclass correlation (ICC), typical error (TE) and coefficient of variation (CV). High levels of reproducibility were observed for MAF (TE = 2.6 N; CV = 4.3 %; ICC = 0.98) and VO2-intensity relationship parameters, as intercept (TE = 0.01 L.min(-1); CV = 11.4 %; ICC = 0.97), slope (TE = 0.002 L.min(-1). N-1; CV = 3.1 %; ICC = 0.97) and coefficient of determination (TE = 0.02; CV = 1.8 %; ICC = 0.47). The MAOD values measured during the test (2.9 +/- 1.1 L and 45.3 +/- 14.0 mL. Kg(-1)) and retests (2.9 +/- 1.1 L and 45.2 +/- 12.6 mL. Kg(-1)) were highly correlated (absolute values: ICC = 0.93; relative to body mass values: ICC = 0.89) and presented low values of TE (0.3 L and 4.3 mL. Kg(-1)) and CV (9.5 % for absolute and 9.6 % for relative to body mass values). Thus, we demonstrated the potential use of tethered swimming to assess anaerobic capacity in an aquatic environment.en
dc.description.affiliationUniv Sao Paulo, Rehabil & Funct Performance, Ave Bandeirantes 3900 Monte Alegre, Ribeirao Preto, Brazil
dc.description.affiliationSao Paulo State Univ, Physiotherapy, Presidente Prudente, Brazil
dc.description.affiliationUniv Sao Paulo, Sch Phys Educ & Sport Ribeirao Preto, Ribeirao Preto, Brazil
dc.description.affiliationUniv Estadual Campinas, Sport Sci, Campinas, SP, Brazil
dc.description.affiliationSao Paulo State Univ, Dept Phys Educ, Bauru, Brazil
dc.description.affiliationUnespSao Paulo State Univ, Physiotherapy, Presidente Prudente, Brazil
dc.description.affiliationUnespSao Paulo State Univ, Dept Phys Educ, Bauru, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 2011/05357-9
dc.description.sponsorshipIdFAPESP: 2011/16195-0
dc.format.extent687-693
dc.identifierhttp://dx.doi.org/10.1055/s-0035-1559696
dc.identifier.citationInternational Journal Of Sports Medicine. Stuttgart: Georg Thieme Verlag Kg, v. 37, n. 9, p. 687-693, 2016.
dc.identifier.doi10.1055/s-0035-1559696
dc.identifier.issn0172-4622
dc.identifier.urihttp://hdl.handle.net/11449/161785
dc.identifier.wosWOS:000380777400003
dc.language.isoeng
dc.publisherGeorg Thieme Verlag Kg
dc.relation.ispartofInternational Journal Of Sports Medicine
dc.relation.ispartofsjr1,217
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectanaerobic capacity
dc.subjectreproducibility
dc.subjectswimmers
dc.titleDetermination of VO2-Intensity Relationship and MAOD in Tethered Swimmingen
dc.typeArtigo
dcterms.rightsHolderGeorg Thieme Verlag Kg
unesp.author.lattes2545518618024469[5]
unesp.author.orcid0000-0003-1065-4158[5]
unesp.departmentEducação Física - FCpt