Study on soluble heavy metals with preconcentration by using a new modified oligosilsesquioxane sorbent

Nenhuma Miniatura disponível

Data

2012-10-30

Orientador

Coorientador

Pós-graduação

Curso de graduação

Título da Revista

ISSN da Revista

Título de Volume

Editor

Elsevier B.V.

Tipo

Artigo

Direito de acesso

Acesso restrito

Resumo

In this work, a new modified oligosilsesquioxane was prepared, characterized and evaluated for its heavy metal adsorption characteristics from aqueous solution. The material was characterized using infrared spectroscopy, X-ray diffractometry, solid-state Si-29 and C-13 nuclear magnetic resonance. Batch and column experiments were conducted to investigate for Fe (III), Cr (III), Cu (II), Cd (II), Pb (II) and Ni (II) removal from dilute aqueous solution by sorption onto modified oligosilsesquioxane. The results obtained in the flow experiments, showed a recovery of ca. 100% of the metal ions adsorbed in a column packed with 2.0 g of nanomaterial, using 3 mL of 1.0 mol L-1 HCl solution as eluent. The detection limits for Fe, Cr, Cu, Cd, Pb, and Ni were 0.26, 0.33, 0.38, 0.41, 0.47 and 0.55 mu g L-1, respectively. The relative standard deviation values (n = 12) were <4.82% for Fe, <4.12% for Cr, <3.79% for Cu, <3.03% for Cd, <4.02% for Pb and <2.65% for Ni. The proposed method was successfully applied to the analysis of environmental samples.

Descrição

Idioma

Inglês

Como citar

Journal of Hazardous Materials. Amsterdam: Elsevier B.V., v. 237, p. 215-222, 2012.