A matheuristic for the selection of beam directions and dose distribution in radiotherapy planning
dc.contributor.author | Obal, Thalita Monteiro | |
dc.contributor.author | Silva, Helenice de Oliveira Florentino [UNESP] | |
dc.contributor.author | Gevert, Vânia Gryczak | |
dc.contributor.author | Jones, Dylan F. | |
dc.contributor.author | Ouelhadj, Djamila | |
dc.contributor.author | Volpi, Neida Maria Patias | |
dc.contributor.author | Wilhelm, Volmir Eugênio | |
dc.contributor.institution | Universidade Federal do Paraná (UFPR) | |
dc.contributor.institution | Universidade Tecnológica Federal do Paraná (UTFPR) | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | University of Portsmouth | |
dc.date.accessioned | 2016-04-01T18:44:27Z | |
dc.date.available | 2016-04-01T18:44:27Z | |
dc.date.issued | 2015 | |
dc.description.abstract | In this paper a matheuristic using a combined Genetic Algorithm (GA) and exact method approach is proposed for selecting the position of the beams and dose distribution in Intensity Modulated Radiotherapy Planning (IMRT). GA selects a set of beams, for which the dose distribution is determined in the process of the GA’s evaluation, using an optimisation model that is solved by an Interior Point method. Two instances are used to evaluate the performance of the matheuristic, comparing to the optimum solution, in terms of solution and computation time, found using the exact methodology of Branch and Bound. The results show that the matheuristic is appropriate to this problem in the case study proposed, as it is extremely faster than the exact method and also have reached the optimum solution in several experiments done. | en |
dc.description.affiliation | Universidade Federal do Paraná (UFPR), Curitiba, PR, Brasil | |
dc.description.affiliation | Universidade Tecnológica Federal do Paraná (UTFPR), Guarapuava, PR, Brasil | |
dc.description.affiliation | Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP), Instituto de Biociências Botucatu (IBB), Departamento de Bioestatística, Botucatu, SP, Brasil | |
dc.description.affiliation | University of Portsmouth, Portsmouth, UK | |
dc.description.affiliationUnesp | Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP), Instituto de Biociências Botucatu (IBB), Departamento de Bioestatística, Botucatu, SP, Brasil | |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | |
dc.format.extent | 1-10 | |
dc.identifier | http://dx.doi.org/10.1088/1742-6596/616/1/012012 | |
dc.identifier.citation | Journal of Physics. Conference Series, v. 616, p. 1-10, 2015. | |
dc.identifier.doi | 10.1088/1742-6596/616/1/012012 | |
dc.identifier.file | ISSN1742-6588-2015-616-01-10.pdf | |
dc.identifier.issn | 1742-6588 | |
dc.identifier.lattes | 9853363280628232 | |
dc.identifier.uri | http://hdl.handle.net/11449/137162 | |
dc.language.iso | eng | |
dc.relation.ispartof | Journal of Physics. Conference Series | |
dc.relation.ispartofsjr | 0,241 | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Currículo Lattes | |
dc.title | A matheuristic for the selection of beam directions and dose distribution in radiotherapy planning | en |
dc.type | Artigo | |
unesp.author.lattes | 9853363280628232 | |
unesp.author.orcid | 0000-0003-2740-8826[2] | |
unesp.campus | Universidade Estadual Paulista (Unesp), Instituto de Biociências, Botucatu | pt |
unesp.department | Bioestatística - IBB | pt |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- ISSN1742-6588-2015-616-01-10.pdf
- Tamanho:
- 1.05 MB
- Formato:
- Adobe Portable Document Format