A matheuristic for the selection of beam directions and dose distribution in radiotherapy planning

dc.contributor.authorObal, Thalita Monteiro
dc.contributor.authorSilva, Helenice de Oliveira Florentino [UNESP]
dc.contributor.authorGevert, Vânia Gryczak
dc.contributor.authorJones, Dylan F.
dc.contributor.authorOuelhadj, Djamila
dc.contributor.authorVolpi, Neida Maria Patias
dc.contributor.authorWilhelm, Volmir Eugênio
dc.contributor.institutionUniversidade Federal do Paraná (UFPR)
dc.contributor.institutionUniversidade Tecnológica Federal do Paraná (UTFPR)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversity of Portsmouth
dc.date.accessioned2016-04-01T18:44:27Z
dc.date.available2016-04-01T18:44:27Z
dc.date.issued2015
dc.description.abstractIn this paper a matheuristic using a combined Genetic Algorithm (GA) and exact method approach is proposed for selecting the position of the beams and dose distribution in Intensity Modulated Radiotherapy Planning (IMRT). GA selects a set of beams, for which the dose distribution is determined in the process of the GA’s evaluation, using an optimisation model that is solved by an Interior Point method. Two instances are used to evaluate the performance of the matheuristic, comparing to the optimum solution, in terms of solution and computation time, found using the exact methodology of Branch and Bound. The results show that the matheuristic is appropriate to this problem in the case study proposed, as it is extremely faster than the exact method and also have reached the optimum solution in several experiments done.en
dc.description.affiliationUniversidade Federal do Paraná (UFPR), Curitiba, PR, Brasil
dc.description.affiliationUniversidade Tecnológica Federal do Paraná (UTFPR), Guarapuava, PR, Brasil
dc.description.affiliationUniversidade Estadual Paulista Júlio de Mesquita Filho (UNESP), Instituto de Biociências Botucatu (IBB), Departamento de Bioestatística, Botucatu, SP, Brasil
dc.description.affiliationUniversity of Portsmouth, Portsmouth, UK
dc.description.affiliationUnespUniversidade Estadual Paulista Júlio de Mesquita Filho (UNESP), Instituto de Biociências Botucatu (IBB), Departamento de Bioestatística, Botucatu, SP, Brasil
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.format.extent1-10
dc.identifierhttp://dx.doi.org/10.1088/1742-6596/616/1/012012
dc.identifier.citationJournal of Physics. Conference Series, v. 616, p. 1-10, 2015.
dc.identifier.doi10.1088/1742-6596/616/1/012012
dc.identifier.fileISSN1742-6588-2015-616-01-10.pdf
dc.identifier.issn1742-6588
dc.identifier.lattes9853363280628232
dc.identifier.urihttp://hdl.handle.net/11449/137162
dc.language.isoeng
dc.relation.ispartofJournal of Physics. Conference Series
dc.relation.ispartofsjr0,241
dc.rights.accessRightsAcesso aberto
dc.sourceCurrículo Lattes
dc.titleA matheuristic for the selection of beam directions and dose distribution in radiotherapy planningen
dc.typeArtigo
unesp.author.lattes9853363280628232
unesp.author.orcid0000-0003-2740-8826[2]
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Biociências, Botucatupt
unesp.departmentBioestatística - IBBpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
ISSN1742-6588-2015-616-01-10.pdf
Tamanho:
1.05 MB
Formato:
Adobe Portable Document Format