Publicação:
A novel device for greater precision and safety in open-wedge high tibial osteotomy: cadaveric study

dc.contributor.authorRibeiro, Cristiano Hossri
dc.contributor.authorMod, Mauricio Sante Bettio
dc.contributor.authorIsch, Daniel
dc.contributor.authorBaier, Clemens
dc.contributor.authorMaderbacher, Guenther
dc.contributor.authorSeverino, Nilson Roberto
dc.contributor.authorCataneo, Daniele Cristina [UNESP]
dc.contributor.institutionHospital Orto
dc.contributor.institutionÁpice Clinic
dc.contributor.institutionSafrima
dc.contributor.institutionAsklepios Klinik
dc.contributor.institutionSanta Casa de Misericórdia de São Paulo (SCSP)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2020-12-12T02:23:44Z
dc.date.available2020-12-12T02:23:44Z
dc.date.issued2020-02-01
dc.description.abstractIntroduction: The complications of the open-wedge osteotomy technique (slope, hypo- and hypercorrection and fractures) are related to difficulties in the control of the open-wedge angle during surgery. Materials and methods: In this cadaveric study, we evaluated the safety and precision of a novel system, the Realignment High Control System (RHC), in the correction of knee mechanical axis and slope. The RHC has a fixation plate coupled to a dynamic device that opens the osteotomy continuously, allowing plate fixation before osteotomy wedge opening. Results: All procedures were easily performed, with no fractures. The openings equaled the indicated by the navigation system for 7.5° and 10°, and for 5°, there was a statistically, although not clinically significant, difference of 0.6°. The slope shown by the RHC setting and in the navigation system was significantly different for the 10° setting only, with a mean difference of 0.563°. Conclusions: RHC facilitates the surgical technique of high tibial osteotomy, with gradual wedge opening, precise correction of the mechanical axis, and appropriate control of the tibial slope, even with larger openings.en
dc.description.affiliationKnee Surgery Division Hospital Orto, Av. Nove de Julho, 1017, Vila Icaraí
dc.description.affiliationÁpice Clinic
dc.description.affiliationSafrima
dc.description.affiliationAsklepios Klinik
dc.description.affiliationDepartment of Orthopedics and Traumatology Santa Casa de Misericórdia de São Paulo (SCSP)
dc.description.affiliationSurgery and Orthopaedics Department Universidade Estadual de São Paulo (Unesp)
dc.description.affiliationUnespSurgery and Orthopaedics Department Universidade Estadual de São Paulo (Unesp)
dc.format.extent203-208
dc.identifierhttp://dx.doi.org/10.1007/s00402-019-03300-w
dc.identifier.citationArchives of Orthopaedic and Trauma Surgery, v. 140, n. 2, p. 203-208, 2020.
dc.identifier.doi10.1007/s00402-019-03300-w
dc.identifier.issn1434-3916
dc.identifier.issn0936-8051
dc.identifier.scopus2-s2.0-85075161225
dc.identifier.urihttp://hdl.handle.net/11449/201086
dc.language.isoeng
dc.relation.ispartofArchives of Orthopaedic and Trauma Surgery
dc.sourceScopus
dc.subjectComputer-assisted surgery
dc.subjectGenu varum
dc.subjectHigh-tibial-osteotomy
dc.subjectKnee osteoarthritis
dc.subjectSurgical technique
dc.titleA novel device for greater precision and safety in open-wedge high tibial osteotomy: cadaveric studyen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.orcid0000-0003-4021-1198[1]
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Medicina, Botucatupt
unesp.departmentCirurgia e Ortopedia - FMBpt

Arquivos