Publicação:
Preparation of a clay-modified carbon paste electrode based on 2-thiazoline-2-thiol-hexadecylammonium sorption for the sensitive determination of mercury

dc.contributor.authorDias Filho, Newton L. [UNESP]
dc.contributor.authorCarmo, Devaney R. do [UNESP]
dc.contributor.authorGessner, Fergus
dc.contributor.authorRosa, André H. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2014-05-27T11:21:40Z
dc.date.available2014-05-27T11:21:40Z
dc.date.issued2005-11-01
dc.description.abstractA montmorillonite from Wyoming-USA was used to prepare an organo-clay complex, named 2-thiazoline-2-thiol-hexadecyltrimethylammonium-clay (TZT-HDTA-clay), for the purpose of the selective adsorption of the heavy metals ions and possible use as a chemically modified carbon paste electrode (CMCPE). Adsorption isotherms of Hg 2+, Pb 2+, Cd 2+, Cu 2+, and Zn 2+ from aqueous solutions as a function of the pH were studied at 298 K. Conditions for quantitative retention and elution were established for each metal by batch and column methods. The organo-clay complex was very selective to Hg(II) in aqueous solution in which other metals and ions were also present. The accumulation voltammetry of Hg(II) was studied at a carbon paste electrode chemically modified with this material. The mercury response was evaluated with respect to the pH, electrode composition, preconcentration time, mercury concentration, cleaning solution, possible interferences and other variables. A carbon paste electrode modified by TZT-HDTA-clay showed two peaks: one cathodic peak at about 0.0 V and an anodic peak at 0.25 V, scanning the potential from -0.2 to 0.8 V (0.05 M KNO 3 vs. Ag/AgCl). The anodic peak at 0.25 V presents excellent selectivity for Hg(II) ions in the presence of foreign ions. The detection limit was estimated as 0.1 μg L -1. The precision of determination was satisfactory for the respective concentration level. 2005 © The Japan Society for Analytical Chemistry.en
dc.description.affiliationDepartamento de Física e Química Unesp-Universidade Estadual Paulista, Av. Brasil, 56-Centro, C. P. 31, 15385-000 Ilha Solteira, SP
dc.description.affiliationInstituto de Química de São Carlos Universidade de São Paulo, C. P. 369, 13560-970 São Carlos, SP
dc.description.affiliationDepartamento de Engenharia Ambiental Unesp-Universidade Estadual Paulista, CEP 18087-180, Sorocaba, SP
dc.description.affiliationUnespDepartamento de Física e Química Unesp-Universidade Estadual Paulista, Av. Brasil, 56-Centro, C. P. 31, 15385-000 Ilha Solteira, SP
dc.description.affiliationUnespDepartamento de Engenharia Ambiental Unesp-Universidade Estadual Paulista, CEP 18087-180, Sorocaba, SP
dc.format.extent1309-1316
dc.identifierhttp://dx.doi.org/10.2116/analsci.21.1309
dc.identifier.citationAnalytical Sciences, v. 21, n. 11, p. 1309-1316, 2005.
dc.identifier.doi10.2116/analsci.21.1309
dc.identifier.file2-s2.0-28444487444.pdf
dc.identifier.issn0910-6340
dc.identifier.issn1348-2246
dc.identifier.orcid0000-0002-2042-018X
dc.identifier.scopus2-s2.0-28444487444
dc.identifier.urihttp://hdl.handle.net/11449/132336
dc.identifier.wosWOS:000234120400010
dc.language.isoeng
dc.relation.ispartofAnalytical Sciences
dc.relation.ispartofjcr1.355
dc.relation.ispartofsjr0,424
dc.relation.ispartofsjr0,424
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subject2-mercaptothiazoline
dc.subjectAluminum silicate
dc.subjectAnion
dc.subjectBentonite
dc.subjectCarbon
dc.subjectCetrimide
dc.subjectDivalent cation
dc.subjectFresh water
dc.subjectMercury
dc.subjectSea water
dc.subjectThiazole derivative
dc.subjectThiazolidine derivative
dc.subjectThyroidan
dc.subjectAdsorption
dc.subjectCalibration
dc.subjectChemistry
dc.subjectClay
dc.subjectElectrochemistry
dc.subjectIon selective electrode
dc.subjectOxidation reduction reaction
dc.subjectPH
dc.subjectReproducibility
dc.subjectX ray diffraction
dc.subjectAdsorption
dc.subjectAluminum Silicates
dc.subjectAnions
dc.subjectBentonite
dc.subjectCalibration
dc.subjectCarbon
dc.subjectCations, Divalent
dc.subjectCetrimonium Compounds
dc.subjectElectrochemistry
dc.subjectFresh Water
dc.subjectHydrogen-Ion Concentration
dc.subjectIon-Selective Electrodes
dc.subjectMercury
dc.subjectOxidation-Reduction
dc.subjectReproducibility of Results
dc.subjectSeawater
dc.subjectThiazoles
dc.subjectThiazolidines
dc.subjectX-Ray Diffraction
dc.titlePreparation of a clay-modified carbon paste electrode based on 2-thiazoline-2-thiol-hexadecylammonium sorption for the sensitive determination of mercuryen
dc.typeArtigo
dcterms.licensehttp://www.jsac.or.jp/analsci/info.php/about.html
dspace.entity.typePublication
unesp.author.lattes5228846314663888[4]
unesp.author.orcid0000-0002-2042-018X[4]
unesp.campusUniversidade Estadual Paulista (Unesp), Instituto de Ciência e Tecnologia, Sorocabapt
unesp.campusUniversidade Estadual Paulista (Unesp), Faculdade de Engenharia, Ilha Solteirapt
unesp.departmentFísica e Química - FEISpt
unesp.departmentEngenharia Ambiental - ICTSpt

Arquivos