Atenção!


O atendimento às questões referentes ao Repositório Institucional será interrompido entre os dias 20 de dezembro de 2024 a 5 de janeiro de 2025.

Pedimos a sua compreensão e aproveitamos para desejar boas festas!

 

Identifying the knee joint angular position under neuromuscular electrical stimulation via long short-term memory neural networks

dc.contributor.authorArcolezi, Héber H. [UNESP]
dc.contributor.authorNunes, Willian R. B. M.
dc.contributor.authorCerna, Selene [UNESP]
dc.contributor.authorde Araujo, Rafael A. [UNESP]
dc.contributor.authorSanches, Marcelo Augusto Assunção [UNESP]
dc.contributor.authorTeixeira, Marcelo Carvalho Minhoto [UNESP]
dc.contributor.authorde Carvalho, Aparecido Augusto [UNESP]
dc.contributor.institutionCNRS
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUTFPR - Federal University of Technology
dc.date.accessioned2020-12-12T02:21:51Z
dc.date.available2020-12-12T02:21:51Z
dc.date.issued2020-01-01
dc.description.abstractPurpose: Recurrent neural networks (RNNs) offer a promising opportunity for identifying nonlinear systems. This paper investigates the effectiveness of the long short-term memory (LSTM) RNN architecture in the specific task of identifying the knee joint angular position under neuromuscular electrical stimulation (NMES). The standard RNN model referred to as SimpleRNN and the well-known multilayer perceptron (MLP) are used for comparison purposes. Methods: Data from seven healthy and two paraplegic volunteers were experimentally acquired. These data were adequately scaled, encoded using three timestep values (1, 5, and 10), and divided into training, validation, and testing sets. These models were mainly evaluated using the root mean square error (RMSE) and training time metrics. Results: The three NN models demonstrated very good fitting to data for all volunteers. The LSTM presented smaller RMSE for most of the individuals. This is even more notable when using 5 and 10 timesteps achieving half and one-third of the error from MLP and half of the error from the SimpleRNN. This higher utility comes with a substantial time-utility trade-off. Conclusion: The results in this paper show that the LSTM worths deeper investigation to design control-oriented models to knee joint stimulation in closed-loop systems. Even though the LSTM takes more time for training due to a more complex architecture, time and computational costs could be increased if achieving better modeling of systems. Rather than mathematically modeling this system with several unique parameters per individual, the use of NNs is encouraged in this task where there exist high nonlinearities and time-varying parameters.en
dc.description.affiliationFemto-ST Institute University Bourgogne Franche-Comté UBFC CNRS
dc.description.affiliationDepartment of Electrical Engineering UNESP – University Estadual Paulista Campus of Ilha Solteira
dc.description.affiliationDepartment of Electrical Engineering UTFPR - Federal University of Technology
dc.description.affiliationUnespDepartment of Electrical Engineering UNESP – University Estadual Paulista Campus of Ilha Solteira
dc.identifierhttp://dx.doi.org/10.1007/s42600-020-00089-1
dc.identifier.citationResearch on Biomedical Engineering.
dc.identifier.doi10.1007/s42600-020-00089-1
dc.identifier.issn2446-4740
dc.identifier.issn2446-4732
dc.identifier.scopus2-s2.0-85090313829
dc.identifier.urihttp://hdl.handle.net/11449/201010
dc.language.isoeng
dc.relation.ispartofResearch on Biomedical Engineering
dc.sourceScopus
dc.subjectKnee joint
dc.subjectLong short-term memory
dc.subjectNeuromuscular electrical stimulation
dc.subjectNonlinear system identification
dc.subjectSpinal cord injury
dc.titleIdentifying the knee joint angular position under neuromuscular electrical stimulation via long short-term memory neural networksen
dc.typeArtigo
unesp.author.orcid0000-0001-8059-7094[1]
unesp.departmentEngenharia Elétrica - FEISpt

Arquivos