Study on the effect of the temperature in Acoustic Emission Sensor by the Pencil Lead Break Test
dc.contributor.author | Lopes, Barbara Guedes [UNESP] | |
dc.contributor.author | Alexandre, Felipe Aparecido [UNESP] | |
dc.contributor.author | Lopes, Wenderson Nascimento [UNESP] | |
dc.contributor.author | Aguiar, Paulo Roberto de [UNESP] | |
dc.contributor.author | Bianchi, Eduardo Carlos [UNESP] | |
dc.contributor.author | Aulestia Viera, Martin Antonio [UNESP] | |
dc.contributor.author | Tsuzuki, MDG | |
dc.contributor.author | Junqueira, F. | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2019-10-04T12:35:39Z | |
dc.date.available | 2019-10-04T12:35:39Z | |
dc.date.issued | 2018-01-01 | |
dc.description.abstract | The Pencil Lead Break (PLB) method is used to reproduce an artificial source of acoustic emission. This method consists of breaking a pencil lead which has its size and thickness determined carefully in a certain angle in a surface. This break releases energy in the form of elastic stress waves which propagate through the structure and are captured and converted into electrical signals by a sensor fixed to the workpiece surface. The PLB method is very efficient in the characterization of acoustic emission sensors. In this paper, the effect of temperature variation in the acoustic emission sensor response was investigated through the PLB method and digital signal processing. The results show that in the frequency response not only the temperature but also the analyzed frequency bands are factors that influence the amplitude of the signals. When comparing signals at different temperatures, the magnitude difference in amplitude increases proportionally to the temperature. | en |
dc.description.affiliation | Sao Paulo State Univ UNESP, Dept Elect Engn, Bauru, Brazil | |
dc.description.affiliation | Sao Paulo State Univ UNESP, Dept Mech Engn, Bauru, Brazil | |
dc.description.affiliationUnesp | Sao Paulo State Univ UNESP, Dept Elect Engn, Bauru, Brazil | |
dc.description.affiliationUnesp | Sao Paulo State Univ UNESP, Dept Mech Engn, Bauru, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorshipId | FAPESP: 2017/18148-5 | |
dc.description.sponsorshipId | FAPESP: 2018/07292-0 | |
dc.format.extent | 1226-1229 | |
dc.identifier.citation | 2018 13th Ieee International Conference On Industry Applications (induscon). New York: Ieee, p. 1226-1229, 2018. | |
dc.identifier.issn | 2572-1445 | |
dc.identifier.lattes | 1455400309660081 | |
dc.identifier.orcid | 0000-0002-9934-4465 | |
dc.identifier.uri | http://hdl.handle.net/11449/185462 | |
dc.identifier.wos | WOS:000459239200184 | |
dc.language.iso | eng | |
dc.publisher | Ieee | |
dc.relation.ispartof | 2018 13th Ieee International Conference On Industry Applications (induscon) | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Web of Science | |
dc.subject | Pencil Lead Break | |
dc.subject | Temperature | |
dc.subject | Acoustic Emission | |
dc.subject | System Monitoring | |
dc.title | Study on the effect of the temperature in Acoustic Emission Sensor by the Pencil Lead Break Test | en |
dc.type | Trabalho apresentado em evento | |
dcterms.license | http://www.ieee.org/publications_standards/publications/rights/rights_policies.html | |
dcterms.rightsHolder | Ieee | |
unesp.author.lattes | 1455400309660081[4] | |
unesp.author.lattes | 1099152007574921[5] | |
unesp.author.orcid | 0000-0002-9934-4465[4] | |
unesp.author.orcid | 0000-0003-2675-4276[5] | |
unesp.department | Engenharia Elétrica - FEB | pt |
unesp.department | Engenharia Mecânica - FEB | pt |